! RefBldgMidriseApartmentNew2004_Chicago.idf ! ! This example file is based on Version 1.3_5.0 and was transitioned to Version 6.0 using the transition utility ! ! DOE Commercial Reference Building ! Midrise Apartment building, new construction 90.1-2004 ! Version 1.3_5.0 ! EnergyPlus Version 6.0 ! ASHRAE Standards 90.1-2004 and 62-1999 ! ! Description: Four story apartment building, 31 apartments plus office ! Form: Area = 3,135 m2 (33,742 ft2); Number of Stories = 4; Shape = rectangle; Aspect ratio = 2.74 ! Envelope: Envelope thermal properties vary with climate according to ASHRAE Standard 90.1-2004 residential. ! Opaque constructions: Steel frame wall; Insulation entirely above deck; slab-on-grade floor ! Windows: window-to-wall ratio = 15.0%, ! Infiltration in perimeter zones only ! = 0.4 cfm/ft2 above grade wall area at 0.3 in wc (75 Pa) adjusted to 0.016 in wc (4 Pa). ! Office: 25% of full value when ventilation system on. ! HVAC: Split system units in each apartment, office; DX cooling and gas furnace ! Economizer per 90.1-2004 for office system only ! ! Int. gains: W/m2 (W/ft2) lights elec plug gas plug ! Apartments 3.88 (0.36) 5.38 (0.50) 0 ! Office 10.8 (1.0) 12.9 (1.20) 0 ! Corridor 5.38 (0.5) 0 0 ! Elevators: 1 @ 20 HP, 91% motor efficiency ! ! Detached Shading: None ! Daylight: None ! Natural Ventilation: None ! Zonal Equipment: ZoneHVAC:UnitHeater (corridor zones)) ! Air Primary Loops: SPLITSYSTEMAC:1; SPLITSYSTEMAC:2;... ! Plant Loops: SHWSys1 ! System Equipment Autosize: Yes ! Purchased Cooling: None ! Purchased Heating: None ! Coils: Coil:Cooling:DX:SingleSpeed; Coil:Heating:Fuel (apartment zones) ! Coil:Heating:Electric (corridor zones) ! Pumps: None ! Boilers: None ! Chillers: None !***** NOTICE ***** !***** The Reference Buildings were prepared as an account of work sponsored by an ***** !***** agency of the United States government. Neither the United States ***** !***** government nor any agency thereof, nor any of their employees, makes ***** !***** any warranty, express or implied, or assumes any legal liability or ***** !***** responsibility for the accuracy, completeness, or usefulness of any ***** !***** information, apparatus, product, or process disclosed, or represents ***** !***** that its use would not infringe privately owned rights. Reference ***** !***** herein to any specific commercial product, process, or service by ***** !***** trade name, trademark, manufacturer, or otherwise does not necessarily ***** !***** constitute or imply its endorsement, recommendation, or favoring by ***** !***** the United States government or any agency thereof. The views and ***** !***** opinions of authors expressed herein do not necessarily state or ***** !***** reflect those of the United States government or any agency thereof. ***** !***** Access to and use of the Reference Buildings imposes the following obligations ***** !***** on the user. The user agrees to credit DOE, NREL, PNNL, and LBNL in ***** !***** any publication(s) that that result from the use of Reference Buildings. ***** !***** However, the names of DOE/NREL/PNNL/LBNL may not be used in any ***** !***** advertising or publicity that implies endorsement or promotion of any ***** !***** products, services or commercial entities. ***** ! Reference citation for the Commercial Reference Buildings: ! Deru, M.; Field, K.; Studer, D.; Benne, K.; Griffith, B.; Torcellini, P; ! Halverson, M.; Winiarski, D.; Liu, B.; Rosenberg, M.; Huang, J.; ! Yazdanian, M.; Crawley, D. (2010). ! U.S. Department of Energy Commercial Reference Building Models of the National Building Stock. ! Washington, DC: U.S. Department of Energy, Energy Efficiency and ! Renewable Energy, Office of Building Technologies. ! ***GENERAL SIMULATION PARAMETERS*** ! Number of Zones: 27 Version,25.1; SimulationControl, YES, !- Do Zone Sizing Calculation YES, !- Do System Sizing Calculation YES, !- Do Plant Sizing Calculation YES, !- Run Simulation for Sizing Periods NO, !- Run Simulation for Weather File Run Periods No, !- Do HVAC Sizing Simulation for Sizing Periods 1; !- Maximum Number of HVAC Sizing Simulation Passes Building, Ref Bldg Midrise Apartment New2004_v1.3_5.0, !- Name 0.0000, !- North Axis {deg} City, !- Terrain 0.0400, !- Loads Convergence Tolerance Value {W} 0.2000, !- Temperature Convergence Tolerance Value {deltaC} FullInteriorAndExterior, !- Solar Distribution 25, !- Maximum Number of Warmup Days 6; !- Minimum Number of Warmup Days RunPeriod, Run Period 1, !- Name 1, !- Begin Month 1, !- Begin Day of Month , !- Begin Year 12, !- End Month 31, !- End Day of Month , !- End Year Sunday, !- Day of Week for Start Day No, !- Use Weather File Holidays and Special Days No, !- Use Weather File Daylight Saving Period No, !- Apply Weekend Holiday Rule Yes, !- Use Weather File Rain Indicators Yes; !- Use Weather File Snow Indicators ! ***HOLIDAYS & DAYLIGHT SAVINGS*** RunPeriodControl:DaylightSavingTime, 2nd Sunday in March, !- Start Date 1st Sunday in November; !- End Date RunPeriodControl:SpecialDays, New Years Day, !- Name January 1, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Veterans Day, !- Name November 11, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Christmas, !- Name December 25, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Independence Day, !- Name July 4, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, MLK Day, !- Name 3rd Monday in January, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Presidents Day, !- Name 3rd Monday in February, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Memorial Day, !- Name Last Monday in May, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Labor Day, !- Name 1st Monday in September, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Columbus Day, !- Name 2nd Monday in October, !- Start Date 1, !- Duration {days} Holiday; !- Special Day Type RunPeriodControl:SpecialDays, Thanksgiving, !- Name 4th Thursday in November,!- Start Date 1, !- Duration {days} Holiday; !- Special Day Type ! ***SCHEDULE TYPES*** ScheduleTypeLimits, Any Number; !- Name ScheduleTypeLimits, Fraction, !- Name 0.0, !- Lower Limit Value 1.0, !- Upper Limit Value CONTINUOUS; !- Numeric Type ScheduleTypeLimits, Temperature, !- Name -60, !- Lower Limit Value 200, !- Upper Limit Value CONTINUOUS; !- Numeric Type ScheduleTypeLimits, On/Off, !- Name 0, !- Lower Limit Value 1, !- Upper Limit Value DISCRETE; !- Numeric Type ScheduleTypeLimits, Control Type, !- Name 0, !- Lower Limit Value 4, !- Upper Limit Value DISCRETE; !- Numeric Type ScheduleTypeLimits, Humidity, !- Name 10, !- Lower Limit Value 90, !- Upper Limit Value CONTINUOUS; !- Numeric Type ScheduleTypeLimits, Number; !- Name ! ***ALWAYS ON SCHEDULE*** Schedule:Compact, ALWAYS_ON, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 ! ***MISC SIMULATION PARAMETERS*** SurfaceConvectionAlgorithm:Inside,TARP; SurfaceConvectionAlgorithm:Outside,DOE-2; HeatBalanceAlgorithm,ConductionTransferFunction,200.0000; ZoneAirHeatBalanceAlgorithm, AnalyticalSolution; !- Algorithm Sizing:Parameters, 1.33, !- Heating Sizing Factor 1.33, !- Cooling Sizing Factor 6; !- Timesteps in Averaging Window ConvergenceLimits, 2, !- Minimum System Timestep {minutes} 25; !- Maximum HVAC Iterations ShadowCalculation, PolygonClipping, !- Shading Calculation Method Periodic, !- Shading Calculation Update Frequency Method 7, !- Shading Calculation Update Frequency 15000; !- Maximum Figures in Shadow Overlap Calculations Timestep,6; ! WeatherFileName=USA_IL_Chicago-OHare_TMY2.epw Site:Location, USA IL-CHICAGO-OHARE, !- Name 41.77, !- Latitude {deg} -87.75, !- Longitude {deg} -6.00, !- Time Zone {hr} 190; !- Elevation {m} ! CHICAGO_IL_USA Annual Heating 99.6%, MaxDB=-20.6°C SizingPeriod:DesignDay, CHICAGO Ann Htg 99.6% Condns DB, !- Name 1, !- Month 21, !- Day of Month WinterDesignDay, !- Day Type -20.6, !- Maximum Dry-Bulb Temperature {C} 0.0, !- Daily Dry-Bulb Temperature Range {deltaC} , !- Dry-Bulb Temperature Range Modifier Type , !- Dry-Bulb Temperature Range Modifier Day Schedule Name Wetbulb, !- Humidity Condition Type -20.6, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} , !- Humidity Condition Day Schedule Name , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} , !- Enthalpy at Maximum Dry-Bulb {J/kg} , !- Daily Wet-Bulb Temperature Range {deltaC} 99063., !- Barometric Pressure {Pa} 4.9, !- Wind Speed {m/s} 270, !- Wind Direction {deg} No, !- Rain Indicator No, !- Snow Indicator No, !- Daylight Saving Time Indicator ASHRAEClearSky, !- Solar Model Indicator , !- Beam Solar Day Schedule Name , !- Diffuse Solar Day Schedule Name , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} 0.00; !- Sky Clearness ! CHICAGO_IL_USA Annual Cooling (WB=>MDB) .4%, MDB=31.2°C WB=25.5°C SizingPeriod:DesignDay, CHICAGO Ann Clg .4% Condns WB=>MDB, !- Name 7, !- Month 21, !- Day of Month SummerDesignDay, !- Day Type 31.2, !- Maximum Dry-Bulb Temperature {C} 10.7, !- Daily Dry-Bulb Temperature Range {deltaC} , !- Dry-Bulb Temperature Range Modifier Type , !- Dry-Bulb Temperature Range Modifier Day Schedule Name Wetbulb, !- Humidity Condition Type 25.5, !- Wetbulb or DewPoint at Maximum Dry-Bulb {C} , !- Humidity Condition Day Schedule Name , !- Humidity Ratio at Maximum Dry-Bulb {kgWater/kgDryAir} , !- Enthalpy at Maximum Dry-Bulb {J/kg} , !- Daily Wet-Bulb Temperature Range {deltaC} 99063., !- Barometric Pressure {Pa} 5.3, !- Wind Speed {m/s} 230, !- Wind Direction {deg} No, !- Rain Indicator No, !- Snow Indicator No, !- Daylight Saving Time Indicator ASHRAEClearSky, !- Solar Model Indicator , !- Beam Solar Day Schedule Name , !- Diffuse Solar Day Schedule Name , !- ASHRAE Clear Sky Optical Depth for Beam Irradiance (taub) {dimensionless} , !- ASHRAE Clear Sky Optical Depth for Diffuse Irradiance (taud) {dimensionless} 1.00; !- Sky Clearness Site:WaterMainsTemperature, CORRELATION, !- Calculation Method , !- Temperature Schedule Name 9.69, !- Annual Average Outdoor Air Temperature {C} 28.10; !- Maximum Difference In Monthly Average Outdoor Air Temperatures {deltaC} Site:GroundTemperature:BuildingSurface,19.527,19.502,19.536,19.598,20.002,21.640,22.225,22.375,21.449,20.121,19.802,19.633; ! ***OPAQUE CONSTRUCTIONS AND MATERIALS*** ! Exterior Walls Construction, Steel Frame Res Ext Wall,!- Name Wood Siding, !- Outside Layer Steel Frame Res Wall Insulation, !- Layer 2 1/2IN Gypsum; !- Layer 3 Material, Steel Frame Res Wall Insulation, !- Name MediumRough, !- Roughness 0.119161363096001, !- Thickness {m} 0.049, !- Conductivity {W/m-K} 265.0000, !- Density {kg/m3} 836.8000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.7000; !- Visible Absorptance ! Roof Construction, IEAD Res Roof, !- Name Roof Membrane, !- Outside Layer IEAD Res Roof Insulation,!- Layer 2 Metal Decking; !- Layer 3 Material, IEAD Res Roof Insulation,!- Name MediumRough, !- Roughness 0.127338688569477, !- Thickness {m} 0.049, !- Conductivity {W/m-K} 265.0000, !- Density {kg/m3} 836.8000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.7000; !- Visible Absorptance ! Slab on grade, unheated Construction, ext-slab, !- Name HW CONCRETE, !- Outside Layer CP02 CARPET PAD; !- Layer 2 ! Interior Walls Construction, int-walls, !- Name 1/2IN Gypsum, !- Outside Layer 1/2IN Gypsum; !- Layer 2 ! Interior Floors Construction, INT-FLOOR-TOPSIDE, !- Name MAT-CC05 4 HW CONCRETE, !- Outside Layer CP02 CARPET PAD; !- Layer 2 Construction, INT-FLOOR-UNDERSIDE, !- Name CP02 CARPET PAD, !- Outside Layer MAT-CC05 4 HW CONCRETE; !- Layer 2 ! ***WINDOW/DOOR CONSTRUCTIONS AND MATERIALS*** Construction, Window Res Operable, !- Name Res Operable Assembly Window; !- Outside Layer WindowMaterial:SimpleGlazingSystem, Res Operable Assembly Window, !- Name 3.80426, !- U-Factor {W/m2-K} 0.39, !- Solar Heat Gain Coefficient ; !- Visible Transmittance ! ***COMMON CONSTRUCTIONS AND MATERIALS*** Construction, InteriorFurnishings, !- Name Std Wood 6inch; !- Outside Layer Material, Std Wood 6inch, !- Name MediumSmooth, !- Roughness 0.15, !- Thickness {m} 0.12, !- Conductivity {W/m-K} 540.0000, !- Density {kg/m3} 1210, !- Specific Heat {J/kg-K} 0.9000000, !- Thermal Absorptance 0.7000000, !- Solar Absorptance 0.7000000; !- Visible Absorptance Material, Wood Siding, !- Name MediumSmooth, !- Roughness 0.0100, !- Thickness {m} 0.1100, !- Conductivity {W/m-K} 544.6200, !- Density {kg/m3} 1210.0000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7800, !- Solar Absorptance 0.7800; !- Visible Absorptance Material, 1/2IN Gypsum, !- Name Smooth, !- Roughness 0.0127, !- Thickness {m} 0.1600, !- Conductivity {W/m-K} 784.9000, !- Density {kg/m3} 830.0000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.9200, !- Solar Absorptance 0.9200; !- Visible Absorptance Material, 1IN Stucco, !- Name Smooth, !- Roughness 0.0253, !- Thickness {m} 0.6918, !- Conductivity {W/m-K} 1858.0000, !- Density {kg/m3} 837.0000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.9200, !- Solar Absorptance 0.9200; !- Visible Absorptance Material, 8IN CONCRETE HW, !- Name Rough, !- Roughness 0.2032, !- Thickness {m} 1.3110, !- Conductivity {W/m-K} 2240.0000, !- Density {kg/m3} 836.8000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.7000; !- Visible Absorptance Material, Metal Siding, !- Name Smooth, !- Roughness 0.0015, !- Thickness {m} 44.9600, !- Conductivity {W/m-K} 7688.8600, !- Density {kg/m3} 410.0000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.2000, !- Solar Absorptance 0.2000; !- Visible Absorptance Material, HW CONCRETE, !- Name Rough, !- Roughness 0.1016, !- Thickness {m} 1.3110, !- Conductivity {W/m-K} 2240.0000, !- Density {kg/m3} 836.8000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.7000; !- Visible Absorptance Material:NoMass, CP02 CARPET PAD, !- Name VeryRough, !- Roughness 0.2165, !- Thermal Resistance {m2-K/W} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.8000; !- Visible Absorptance Material, Roof Membrane, !- Name VeryRough, !- Roughness 0.0095, !- Thickness {m} 0.1600, !- Conductivity {W/m-K} 1121.2900, !- Density {kg/m3} 1460.0000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.7000; !- Visible Absorptance Material, Metal Decking, !- Name MediumSmooth, !- Roughness 0.0015, !- Thickness {m} 45.0060, !- Conductivity {W/m-K} 7680.0000, !- Density {kg/m3} 418.4000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.3000; !- Visible Absorptance Material, Metal Roofing, !- Name MediumSmooth, !- Roughness 0.0015, !- Thickness {m} 45.0060, !- Conductivity {W/m-K} 7680.0000, !- Density {kg/m3} 418.4000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.3000; !- Visible Absorptance Material, MAT-CC05 4 HW CONCRETE, !- Name Rough, !- Roughness 0.1016, !- Thickness {m} 1.3110, !- Conductivity {W/m-K} 2240.0000, !- Density {kg/m3} 836.8000, !- Specific Heat {J/kg-K} 0.9000, !- Thermal Absorptance 0.7000, !- Solar Absorptance 0.7000; !- Visible Absorptance ! Acoustic tile for drop ceiling Material, Std AC02, !- Name MediumSmooth, !- Roughness 1.2700000E-02, !- Thickness {m} 5.7000000E-02, !- Conductivity {W/m-K} 288.0000, !- Density {kg/m3} 1339.000, !- Specific Heat {J/kg-K} 0.9000000, !- Thermal Absorptance 0.7000000, !- Solar Absorptance 0.2000000; !- Visible Absorptance Material:NoMass, MAT-AIR-WALL, !- Name Rough, !- Roughness 0.2079491, !- Thermal Resistance {m2-K/W} 0.9, !- Thermal Absorptance 0.7; !- Solar Absorptance ! ZONE LIST: ! G SW Apartment, ! G NW Apartment, ! Office, ! G NE Apartment, ! G N1 Apartment, ! G N2 Apartment, ! G S1 Apartment, ! G S2 Apartment, ! M SW Apartment, ! M NW Apartment, ! M SE Apartment, ! M NE Apartment, ! M N1 Apartment, ! M N2 Apartment, ! M S1 Apartment, ! M S2 Apartment, ! T SW Apartment, ! T NW Apartment, ! T SE Apartment, ! T NE Apartment, ! T N1 Apartment, ! T N2 Apartment, ! T S1 Apartment, ! T S2 Apartment, ! T Corridor, ! G Corridor, ! M Corridor ! ***ZONES*** Zone, G SW Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, G NW Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 9.2959, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, Office, !- Name 0.0000, !- Direction of Relative North {deg} 34.7455, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, G NE Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 34.7455, !- X Origin {m} 9.2959, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, G N1 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 11.5818, !- X Origin {m} 9.2959, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, G N2 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 23.1637, !- X Origin {m} 9.2959, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, G S1 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 11.5818, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, G S2 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 23.1637, !- X Origin {m} 0.0000, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M SW Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M NW Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 9.2959, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M SE Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 34.7455, !- X Origin {m} 0.0000, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M NE Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 34.7455, !- X Origin {m} 9.2959, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M N1 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 11.5818, !- X Origin {m} 9.2959, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M N2 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 23.1637, !- X Origin {m} 9.2959, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M S1 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 11.5818, !- X Origin {m} 0.0000, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M S2 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 23.1637, !- X Origin {m} 0.0000, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T SW Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 0.0000, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T NW Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 9.2959, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T SE Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 34.7455, !- X Origin {m} 0.0000, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T NE Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 34.7455, !- X Origin {m} 9.2959, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T N1 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 11.5818, !- X Origin {m} 9.2959, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T N2 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 23.1637, !- X Origin {m} 9.2959, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T S1 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 11.5818, !- X Origin {m} 0.0000, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T S2 Apartment, !- Name 0.0000, !- Direction of Relative North {deg} 23.1637, !- X Origin {m} 0.0000, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, T Corridor, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 7.6196, !- Y Origin {m} 9.1435, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, G Corridor, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 7.6196, !- Y Origin {m} 0.0000, !- Z Origin {m} 1, !- Type 1, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area Zone, M Corridor, !- Name 0.0000, !- Direction of Relative North {deg} 0.0000, !- X Origin {m} 7.6196, !- Y Origin {m} 3.0478, !- Z Origin {m} 1, !- Type 2, !- Multiplier , !- Ceiling Height {m} , !- Volume {m3} autocalculate, !- Floor Area {m2} , !- Zone Inside Convection Algorithm , !- Zone Outside Convection Algorithm Yes; !- Part of Total Floor Area ! ***WALLS*** ! G SW Apartment BuildingSurface:Detailed, g SWall SWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G SW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g WWall SWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G SW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor SWA, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G SW Apartment, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin SWA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g NIWall SWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name G SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Wall 1, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EIWALL SWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name G SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g WWall S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! G NW Apartment BuildingSurface:Detailed, g NWall NWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G NW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g WWall NWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G NW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor NWA, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G NW Apartment, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin NWA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g SIWall NWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name G NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g NWall C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EIWALL NWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name G NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition G WWall N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! Office BuildingSurface:Detailed, g SWall SEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name Office, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EWall SEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name Office, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor SEA, !- Name Floor, !- Surface Type ext-slab, !- Construction Name Office, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin SEA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name Office, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g NIWall SEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name Office, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g SWall C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g WWall SEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name Office, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g EIWALL S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! G NE Apartment BuildingSurface:Detailed, g NWall NEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G NE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EWall NEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G NE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor NEA, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G NE Apartment, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin NEA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g SIWall NEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name G NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Wall 6, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g WWall NEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name G NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g EIWALL N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! G N1 Apartment BuildingSurface:Detailed, g NWall N1A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G N1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor N1A, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G N1 Apartment, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin N1A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g SIWall N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Wall 4, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EIWALL N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g WWall N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, G WWall N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g EIWALL NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! G N2 Apartment BuildingSurface:Detailed, g NWall N2A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G N2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor N2A, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G N2 Apartment, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin N2A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g SIWall N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Wall 5, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EIWALL N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g WWall NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g WWall N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g EIWALL N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! G S1 Apartment BuildingSurface:Detailed, g SWall S1A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G S1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor S1A, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G S1 Apartment, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin S1A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g NIWall S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Wall 2, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EIWALL S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g WWall S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g WWall S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g EIWALL SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! G S2 Apartment BuildingSurface:Detailed, g SWall S2A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G S2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g GFloor S2A, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G S2 Apartment, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceilin S2A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceilin S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g NIWall S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Wall 3, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EIWALL S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g WWall SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g WWall S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name G S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g EIWALL S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M SW Apartment BuildingSurface:Detailed, m WWall SWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M SW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m GFloor SWA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin SWA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SWall SWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M SW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m NIWall SWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m SWall C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EIWALL SWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m WWall S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M NW Apartment BuildingSurface:Detailed, m NWall NWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M NW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m WWall NWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M NW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m GFloor NWA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin NWA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SIWall NWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Wall 4, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EIWALL NWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m WWall N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M SE Apartment BuildingSurface:Detailed, m EWall SEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M SE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m GFloor SEA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M SE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin SEA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M SE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SWall SEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M SE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m NIWall SEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M SE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Wall 3, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m WWall SEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M SE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m EIWALL S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M NE Apartment BuildingSurface:Detailed, m NWall NEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M NE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EWall NEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M NE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m GFloor NEA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin NEA, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SIWall NEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m NWall C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m WWall NEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name M NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m EIWALL N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M N1 Apartment BuildingSurface:Detailed, m NWall N1A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M N1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m GFloor N1A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin N1A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SIWall N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Wall 5, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EIWALL N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m WWall N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m WWall N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m EIWALL NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M N2 Apartment BuildingSurface:Detailed, m NWall N2A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M N2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m GFloor N2A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin N2A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SIWall N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Wall 6, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EIWALL N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m WWall NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m WWall N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m EIWALL N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M S1 Apartment BuildingSurface:Detailed, m GFloor S1A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin S1A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SWall S1A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M S1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m NIWall S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Wall 1, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EIWALL S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m WWall S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m WWall S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m EIWALL SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M S2 Apartment BuildingSurface:Detailed, m GFloor S2A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m GFloor S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceilin S2A, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceilin S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SWall S2A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M S2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m NIWall S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Wall 2, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EIWALL S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m WWall SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m WWall S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name M S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m EIWALL S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T SW Apartment BuildingSurface:Detailed, t WWall SWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T SW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t GFloor SWA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof SWA, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T SW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SWall SWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T SW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t NIWall SWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t SWall C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EIWALL SWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T SW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t WWall S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T NW Apartment BuildingSurface:Detailed, t NWall NWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T NW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t WWall NWA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T NW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t GFloor NWA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof NWA, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T NW Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SIWall NWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t Wall 1, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EIWALL NWA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T NW Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t WWall N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T SE Apartment BuildingSurface:Detailed, t EWall SEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T SE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t GFloor SEA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T SE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof SEA, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T SE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SWall SEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T SE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t NIWall SEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T SE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t Wall 6, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t WWall SEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T SE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t EIWALL S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T NE Apartment BuildingSurface:Detailed, t NWall NEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T NE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EWall NEA, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T NE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t GFloor NEA, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof NEA, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T NE Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SIWall NEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t NWall C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t WWall NEA, !- Name Wall, !- Surface Type int-walls, !- Construction Name T NE Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t EIWALL N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T N1 Apartment BuildingSurface:Detailed, t NWall N1A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T N1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t GFloor N1A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof N1A, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T N1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SIWall N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t Wall 2, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EIWALL N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t WWall N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t WWall N1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T N1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t EIWALL NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T N2 Apartment BuildingSurface:Detailed, t NWall N2A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T N2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t GFloor N2A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof N2A, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T N2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SIWall N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t Wall 3, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EIWALL N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t WWall NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t WWall N2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T N2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t EIWALL N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T S1 Apartment BuildingSurface:Detailed, t GFloor S1A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof S1A, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T S1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SWall S1A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T S1 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t NIWall S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t Wall 4, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EIWALL S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t WWall S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t WWall S1A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T S1 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t EIWALL SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T S2 Apartment BuildingSurface:Detailed, t GFloor S2A, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t GFloor S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof S2A, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T S2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SWall S2A, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T S2 Apartment, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t NIWall S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t Wall 5, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EIWALL S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t WWall SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,7.6196,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,7.6196,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t WWall S2A, !- Name Wall, !- Surface Type int-walls, !- Construction Name T S2 Apartment, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t EIWALL S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,7.6196,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,7.6196,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! T Corridor BuildingSurface:Detailed, t WWall C, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T Corridor, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t EWall C, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name T Corridor, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 46.3273,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Roof C, !- Name Roof, !- Surface Type IEAD Res Roof, !- Construction Name T Corridor, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,1.6763,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Floor C, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t Floor C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t SWall C, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t NIWall SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t NWall C, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t SIWall NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 34.7455,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 34.7455,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Wall 1, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t SIWall NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Wall 2, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t SIWall N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 23.1636,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 23.1636,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Wall 3, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t SIWall N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 34.7455,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 34.7455,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 23.1636,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 23.1636,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Wall 4, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t NIWall S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 23.1637,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 23.1637,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Wall 5, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t NIWall S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 23.1637,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 23.1637,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 34.7455,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 34.7455,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, t Wall 6, !- Name Wall, !- Surface Type int-walls, !- Construction Name T Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition t NIWall SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 34.7455,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 34.7455,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 46.3273,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! G Corridor BuildingSurface:Detailed, g WWall C, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G Corridor, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Ceiling C, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g Ceiling C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,1.6763,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Floor C, !- Name Floor, !- Surface Type ext-slab, !- Construction Name G Corridor, !- Zone Name , !- Space Name Ground, !- Outside Boundary Condition , !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g SWall C, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g NIWall SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 34.7455,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 34.7455,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 46.3273,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g NWall C, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g SIWall NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g EWall C, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name G Corridor, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 46.3273,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Wall 1, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g NIWall SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Wall 2, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g NIWall S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 23.1636,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 23.1637,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Wall 3, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g NIWall S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 23.1636,0.0000,0.0000, !- X,Y,Z ==> Vertex 1 {m} 34.7455,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 34.7455,0.0000,3.0478, !- X,Y,Z ==> Vertex 3 {m} 23.1637,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Wall 4, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g SIWall N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 23.1636,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 23.1636,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Wall 5, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g SIWall N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 34.7455,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 34.7455,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 23.1636,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 23.1636,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, g Wall 6, !- Name Wall, !- Surface Type int-walls, !- Construction Name G Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition g SIWall NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 34.7455,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 34.7455,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! M Corridor BuildingSurface:Detailed, m WWall C, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M Corridor, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m EWall C, !- Name Wall, !- Surface Type Steel Frame Res Ext Wall,!- Construction Name M Corridor, !- Zone Name , !- Space Name Outdoors, !- Outside Boundary Condition , !- Outside Boundary Condition Object SunExposed, !- Sun Exposure WindExposed, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 46.3273,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Ceiling C, !- Name Ceiling, !- Surface Type INT-FLOOR-UNDERSIDE, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Ceiling C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,3.0478, !- X,Y,Z ==> Vertex 2 {m} 0.0000,1.6763,3.0478, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Floor C, !- Name Floor, !- Surface Type INT-FLOOR-TOPSIDE, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m Floor C, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.0000,0.0000; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m NWall C, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m SIWall NEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 46.3273,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 46.3273,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 34.7455,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 34.7455,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m SWall C, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m NIWall SWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 0.0000,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 0.0000,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Wall 1, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m NIWall S1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 23.1637,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 23.1637,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Wall 2, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m NIWall S2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 23.1637,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 23.1637,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 34.7455,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 34.7455,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Wall 3, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m NIWall SEA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 34.7455,0.0000,3.0478, !- X,Y,Z ==> Vertex 1 {m} 34.7455,0.0000,0.0000, !- X,Y,Z ==> Vertex 2 {m} 46.3273,0.0000,0.0000, !- X,Y,Z ==> Vertex 3 {m} 46.3273,0.0000,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Wall 4, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m SIWall NWA, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 11.5818,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 11.5818,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 0.0000,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 0.0000,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Wall 5, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m SIWall N1A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 23.1636,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 23.1636,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 11.5818,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 11.5818,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} BuildingSurface:Detailed, m Wall 6, !- Name Wall, !- Surface Type int-walls, !- Construction Name M Corridor, !- Zone Name , !- Space Name Surface, !- Outside Boundary Condition m SIWall N2A, !- Outside Boundary Condition Object NoSun, !- Sun Exposure NoWind, !- Wind Exposure AutoCalculate, !- View Factor to Ground 4, !- Number of Vertices 34.7455,1.6763,3.0478, !- X,Y,Z ==> Vertex 1 {m} 34.7455,1.6763,0.0000, !- X,Y,Z ==> Vertex 2 {m} 23.1636,1.6763,0.0000, !- X,Y,Z ==> Vertex 3 {m} 23.1636,1.6763,3.0478; !- X,Y,Z ==> Vertex 4 {m} ! ***WINDOWS*** ! G SW Apartment FenestrationSurface:Detailed, GWindow1, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g SWall SWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, GWindow2, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g WWall SWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,5.1414,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,5.1414,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,2.3983,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,2.3983,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! G NW Apartment FenestrationSurface:Detailed, GWindow4, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g NWall NWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, GWindow6, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g WWall NWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,5.1814,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,5.1814,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,2.4383,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,2.4383,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! Office FenestrationSurface:Detailed, GWindow3, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g SWall SEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, GWindow7, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g EWall SEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 11.5818,2.4383,2.1731, !- X,Y,Z ==> Vertex 1 {m} 11.5818,2.4383,0.9540, !- X,Y,Z ==> Vertex 2 {m} 11.5818,5.1814,0.9540, !- X,Y,Z ==> Vertex 3 {m} 11.5818,5.1814,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! G NE Apartment FenestrationSurface:Detailed, GWindow5, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g NWall NEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, GWindow8, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g EWall NEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 11.5818,2.4383,2.1731, !- X,Y,Z ==> Vertex 1 {m} 11.5818,2.4383,0.9540, !- X,Y,Z ==> Vertex 2 {m} 11.5818,5.1814,0.9540, !- X,Y,Z ==> Vertex 3 {m} 11.5818,5.1814,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! G N1 Apartment FenestrationSurface:Detailed, GWindow9, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g NWall N1A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! G N2 Apartment FenestrationSurface:Detailed, GWindow10, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g NWall N2A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! G S1 Apartment FenestrationSurface:Detailed, GWindow11, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g SWall S1A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! G S2 Apartment FenestrationSurface:Detailed, GWindow12, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g SWall S2A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M SW Apartment FenestrationSurface:Detailed, MWindow2, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m WWall SWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,5.1814,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,5.1814,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,2.4383,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,2.4383,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, MWindow1, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m SWall SWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M NW Apartment FenestrationSurface:Detailed, MWindow4, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m NWall NWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, MWindow6, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m WWall NWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,5.1814,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,5.1814,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,2.4383,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,2.4383,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M SE Apartment FenestrationSurface:Detailed, MWindow7, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m EWall SEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 11.5818,2.4383,2.1731, !- X,Y,Z ==> Vertex 1 {m} 11.5818,2.4383,0.9540, !- X,Y,Z ==> Vertex 2 {m} 11.5818,5.1814,0.9540, !- X,Y,Z ==> Vertex 3 {m} 11.5818,5.1814,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, MWindow3, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m SWall SEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M NE Apartment FenestrationSurface:Detailed, MWindow5, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m NWall NEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, MWindow8, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m EWall NEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 11.5818,2.4383,2.1731, !- X,Y,Z ==> Vertex 1 {m} 11.5818,2.4383,0.9540, !- X,Y,Z ==> Vertex 2 {m} 11.5818,5.1814,0.9540, !- X,Y,Z ==> Vertex 3 {m} 11.5818,5.1814,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M N1 Apartment FenestrationSurface:Detailed, MWindow9, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m NWall N1A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M N2 Apartment FenestrationSurface:Detailed, MWindow10, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m NWall N2A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M S1 Apartment FenestrationSurface:Detailed, MWindow11, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m SWall S1A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! M S2 Apartment FenestrationSurface:Detailed, MWindow12, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m SWall S2A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T SW Apartment FenestrationSurface:Detailed, TWindow2, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t WWall SWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,5.1814,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,5.1814,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,2.4383,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,2.4383,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, TWindow1, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t SWall SWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T NW Apartment FenestrationSurface:Detailed, TWindow4, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t NWall NWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, TWindow6, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t WWall NWA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,5.1814,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,5.1814,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,2.4383,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,2.4383,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T SE Apartment FenestrationSurface:Detailed, TWindow7, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t EWall SEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 11.5818,2.4383,2.1731, !- X,Y,Z ==> Vertex 1 {m} 11.5818,2.4383,0.9540, !- X,Y,Z ==> Vertex 2 {m} 11.5818,5.1814,0.9540, !- X,Y,Z ==> Vertex 3 {m} 11.5818,5.1814,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, TWindow3, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t SWall SEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T NE Apartment FenestrationSurface:Detailed, TWindow5, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t NWall NEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, TWindow8, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t EWall NEA, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 11.5818,2.4383,2.1731, !- X,Y,Z ==> Vertex 1 {m} 11.5818,2.4383,0.9540, !- X,Y,Z ==> Vertex 2 {m} 11.5818,5.1814,0.9540, !- X,Y,Z ==> Vertex 3 {m} 11.5818,5.1814,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T N1 Apartment FenestrationSurface:Detailed, TWindow9, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t NWall N1A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T N2 Apartment FenestrationSurface:Detailed, TWindow10, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t NWall N2A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 7.9240,7.6196,2.1731, !- X,Y,Z ==> Vertex 1 {m} 7.9240,7.6196,0.9540, !- X,Y,Z ==> Vertex 2 {m} 3.6570,7.6196,0.9540, !- X,Y,Z ==> Vertex 3 {m} 3.6570,7.6196,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T S1 Apartment FenestrationSurface:Detailed, TWindow11, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t SWall S1A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T S2 Apartment FenestrationSurface:Detailed, TWindow12, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t SWall S2A, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 3.6570,0.0000,2.1731, !- X,Y,Z ==> Vertex 1 {m} 3.6570,0.0000,0.9540, !- X,Y,Z ==> Vertex 2 {m} 7.9240,0.0000,0.9540, !- X,Y,Z ==> Vertex 3 {m} 7.9240,0.0000,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! T Corridor FenestrationSurface:Detailed, TWindow13, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t WWall C, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,1.2953,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,1.2953,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.3810,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.3810,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, TWindow14, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name t EWall C, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 46.3273,0.3810,2.1731, !- X,Y,Z ==> Vertex 1 {m} 46.3273,0.3810,0.9540, !- X,Y,Z ==> Vertex 2 {m} 46.3273,1.2953,0.9540, !- X,Y,Z ==> Vertex 3 {m} 46.3273,1.2953,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! G Corridor FenestrationSurface:Detailed, GWindow13, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g WWall C, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,1.2953,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,1.2953,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.3810,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.3810,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, east_door, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name g EWall C, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 46.3273,0.0508,2.1335, !- X,Y,Z ==> Vertex 1 {m} 46.3273,0.0508,0.0254, !- X,Y,Z ==> Vertex 2 {m} 46.3273,1.6255,0.0254, !- X,Y,Z ==> Vertex 3 {m} 46.3273,1.6255,2.1335; !- X,Y,Z ==> Vertex 4 {m} ! M Corridor FenestrationSurface:Detailed, MWindow13, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m WWall C, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 0.0000,1.2953,2.1731, !- X,Y,Z ==> Vertex 1 {m} 0.0000,1.2953,0.9540, !- X,Y,Z ==> Vertex 2 {m} 0.0000,0.3810,0.9540, !- X,Y,Z ==> Vertex 3 {m} 0.0000,0.3810,2.1731; !- X,Y,Z ==> Vertex 4 {m} FenestrationSurface:Detailed, MWindow14, !- Name Window, !- Surface Type Window Res Operable, !- Construction Name m EWall C, !- Building Surface Name , !- Outside Boundary Condition Object AutoCalculate, !- View Factor to Ground , !- Frame and Divider Name 1.0000, !- Multiplier 4, !- Number of Vertices 46.3273,0.3810,2.1731, !- X,Y,Z ==> Vertex 1 {m} 46.3273,0.3810,0.9540, !- X,Y,Z ==> Vertex 2 {m} 46.3273,1.2953,0.9540, !- X,Y,Z ==> Vertex 3 {m} 46.3273,1.2953,2.1731; !- X,Y,Z ==> Vertex 4 {m} ! ***GEOMETRY RULES*** GlobalGeometryRules, UpperLeftCorner, !- Starting Vertex Position Counterclockwise, !- Vertex Entry Direction Relative, !- Coordinate System Relative; !- Daylighting Reference Point Coordinate System ! ***PEOPLE*** People, Office People, !- Name Office, !- Zone or ZoneList or Space or SpaceList Name OFF_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.0, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, G SW Apartment People, !- Name G SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, G NW Apartment People, !- Name G NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, G NE Apartment People, !- Name G NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, G N1 Apartment People, !- Name G N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, G N2 Apartment People, !- Name G N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, G S1 Apartment People, !- Name G S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, G S2 Apartment People, !- Name G S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M SW Apartment People, !- Name M SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M NW Apartment People, !- Name M NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M SE Apartment People, !- Name M SE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M NE Apartment People, !- Name M NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M N1 Apartment People, !- Name M N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M N2 Apartment People, !- Name M N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M S1 Apartment People, !- Name M S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, M S2 Apartment People, !- Name M S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T SW Apartment People, !- Name T SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T NW Apartment People, !- Name T NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T SE Apartment People, !- Name T SE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T NE Apartment People, !- Name T NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T N1 Apartment People, !- Name T N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T N2 Apartment People, !- Name T N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T S1 Apartment People, !- Name T S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type People, T S2 Apartment People, !- Name T S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_OCC_SCH, !- Number of People Schedule Name People, !- Number of People Calculation Method 2.5, !- Number of People , !- People per Floor Area {person/m2} , !- Floor Area per Person {m2/person} 0.3000, !- Fraction Radiant AUTOCALCULATE, !- Sensible Heat Fraction ACTIVITY_SCH, !- Activity Level Schedule Name , !- Carbon Dioxide Generation Rate {m3/s-W} No, !- Enable ASHRAE 55 Comfort Warnings EnclosureAveraged, !- Mean Radiant Temperature Calculation Type , !- Surface Name/Angle Factor List Name WORK_EFF_SCH, !- Work Efficiency Schedule Name ClothingInsulationSchedule, !- Clothing Insulation Calculation Method , !- Clothing Insulation Calculation Method Schedule Name CLOTHING_SCH, !- Clothing Insulation Schedule Name AIR_VELO_SCH, !- Air Velocity Schedule Name FANGER; !- Thermal Comfort Model 1 Type ! ***LIGHTS*** Lights, Office_Lights, !- Name Office, !- Zone or ZoneList or Space or SpaceList Name OFF_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 10.76, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G Corridor_Lights, !- Name G Corridor, !- Zone or ZoneList or Space or SpaceList Name COR_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M Corridor_Lights, !- Name M Corridor, !- Zone or ZoneList or Space or SpaceList Name COR_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T Corridor_Lights, !- Name T Corridor, !- Zone or ZoneList or Space or SpaceList Name COR_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G SW Apartment_Lights, !- Name G SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G NW Apartment_Lights, !- Name G NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G NE Apartment_Lights, !- Name G NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G N1 Apartment_Lights, !- Name G N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G N2 Apartment_Lights, !- Name G N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G S1 Apartment_Lights, !- Name G S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, G S2 Apartment_Lights, !- Name G S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M SW Apartment_Lights, !- Name M SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M NW Apartment_Lights, !- Name M NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M SE Apartment_Lights, !- Name M SE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M NE Apartment_Lights, !- Name M NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M N1 Apartment_Lights, !- Name M N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M N2 Apartment_Lights, !- Name M N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M S1 Apartment_Lights, !- Name M S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, M S2 Apartment_Lights, !- Name M S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T SW Apartment_Lights, !- Name T SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T NW Apartment_Lights, !- Name T NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T SE Apartment_Lights, !- Name T SE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T NE Apartment_Lights, !- Name T NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T N1 Apartment_Lights, !- Name T N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T N2 Apartment_Lights, !- Name T N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T S1 Apartment_Lights, !- Name T S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature Lights, T S2 Apartment_Lights, !- Name T S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_LIGHT_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Lighting Level {W} 3.88, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Return Air Fraction 0.7000, !- Fraction Radiant 0.2000, !- Fraction Visible 1.0000, !- Fraction Replaceable General, !- End-Use Subcategory No; !- Return Air Fraction Calculated from Plenum Temperature ! ***EQUIPMENT GAINS*** ElectricEquipment, Office_PlugMisc_Equip, !- Name Office, !- Zone or ZoneList or Space or SpaceList Name OFF_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 12.9, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, G Corridor_Elevators_Equip, !- Name G Corridor, !- Zone or ZoneList or Space or SpaceList Name BLDG_ELEVATORS, !- Schedule Name EquipmentLevel, !- Design Level Calculation Method 16054.9450549451, !- Design Level {W} , !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.0000, !- Fraction Radiant 0.9500, !- Fraction Lost Elevators; !- End-Use Subcategory ElectricEquipment, G SW Apartment_PlugMisc_Equip, !- Name G SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, G NW Apartment_PlugMisc_Equip, !- Name G NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, G NE Apartment_PlugMisc_Equip, !- Name G NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, G N1 Apartment_PlugMisc_Equip, !- Name G N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, G N2 Apartment_PlugMisc_Equip, !- Name G N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, G S1 Apartment_PlugMisc_Equip, !- Name G S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, G S2 Apartment_PlugMisc_Equip, !- Name G S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M SW Apartment_PlugMisc_Equip, !- Name M SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M NW Apartment_PlugMisc_Equip, !- Name M NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M SE Apartment_PlugMisc_Equip, !- Name M SE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M NE Apartment_PlugMisc_Equip, !- Name M NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M N1 Apartment_PlugMisc_Equip, !- Name M N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M N2 Apartment_PlugMisc_Equip, !- Name M N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M S1 Apartment_PlugMisc_Equip, !- Name M S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, M S2 Apartment_PlugMisc_Equip, !- Name M S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T SW Apartment_PlugMisc_Equip, !- Name T SW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T NW Apartment_PlugMisc_Equip, !- Name T NW Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T SE Apartment_PlugMisc_Equip, !- Name T SE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T NE Apartment_PlugMisc_Equip, !- Name T NE Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T N1 Apartment_PlugMisc_Equip, !- Name T N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T N2 Apartment_PlugMisc_Equip, !- Name T N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T S1 Apartment_PlugMisc_Equip, !- Name T S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ElectricEquipment, T S2 Apartment_PlugMisc_Equip, !- Name T S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name APT_EQP_SCH, !- Schedule Name Watts/Area, !- Design Level Calculation Method , !- Design Level {W} 5.38, !- Watts per Zone Floor Area {W/m2} , !- Watts per Person {W/person} 0.0000, !- Fraction Latent 0.5000, !- Fraction Radiant 0.0000, !- Fraction Lost General; !- End-Use Subcategory ! ***EXTERIOR LOADS*** Exterior:Lights, Exterior Facade Lighting,!- Name ALWAYS_ON, !- Schedule Name 5357, !- Design Level {W} AstronomicalClock, !- Control Option Exterior Facade Lighting;!- End-Use Subcategory ! ***INFILTRATION*** ZoneInfiltration:DesignFlowRate, Office_Infiltration, !- Name Office, !- Zone or ZoneList or Space or SpaceList Name OFFICE_INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G Corridor_Infiltration, !- Name G Corridor, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M Corridor_Infiltration, !- Name M Corridor, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T Corridor_Infiltration, !- Name T Corridor, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G SW Apartment_Infiltration, !- Name G SW Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G NW Apartment_Infiltration, !- Name G NW Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G NE Apartment_Infiltration, !- Name G NE Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G N1 Apartment_Infiltration, !- Name G N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G N2 Apartment_Infiltration, !- Name G N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G S1 Apartment_Infiltration, !- Name G S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, G S2 Apartment_Infiltration, !- Name G S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M SW Apartment_Infiltration, !- Name M SW Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M NW Apartment_Infiltration, !- Name M NW Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M SE Apartment_Infiltration, !- Name M SE Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M NE Apartment_Infiltration, !- Name M NE Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M N1 Apartment_Infiltration, !- Name M N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M N2 Apartment_Infiltration, !- Name M N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M S1 Apartment_Infiltration, !- Name M S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, M S2 Apartment_Infiltration, !- Name M S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T SW Apartment_Infiltration, !- Name T SW Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T NW Apartment_Infiltration, !- Name T NW Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T SE Apartment_Infiltration, !- Name T SE Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T NE Apartment_Infiltration, !- Name T NE Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T N1 Apartment_Infiltration, !- Name T N1 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T N2 Apartment_Infiltration, !- Name T N2 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T S1 Apartment_Infiltration, !- Name T S1 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ZoneInfiltration:DesignFlowRate, T S2 Apartment_Infiltration, !- Name T S2 Apartment, !- Zone or ZoneList or Space or SpaceList Name INFIL_SCH, !- Schedule Name Flow/ExteriorArea, !- Design Flow Rate Calculation Method , !- Design Flow Rate {m3/s} , !- Flow per Zone Floor Area {m3/s-m2} 0.000302, !- Flow per Exterior Surface Area {m3/s-m2} , !- Air Changes per Hour {1/hr} 1.0000, !- Constant Term Coefficient 0.0000, !- Temperature Term Coefficient 0.0000, !- Velocity Term Coefficient 0.0000; !- Velocity Squared Term Coefficient ! ***INTERNAL MASS*** InternalMass, Office Internal Mass, !- Name InteriorFurnishings, !- Construction Name Office, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, G Corridor Internal Mass,!- Name InteriorFurnishings, !- Construction Name G Corridor, !- Zone or ZoneList Name , !- Space or SpaceList Name 155.3169; !- Surface Area {m2} InternalMass, M Corridor Internal Mass,!- Name InteriorFurnishings, !- Construction Name M Corridor, !- Zone or ZoneList Name , !- Space or SpaceList Name 155.3169; !- Surface Area {m2} InternalMass, T Corridor Internal Mass,!- Name InteriorFurnishings, !- Construction Name T Corridor, !- Zone or ZoneList Name , !- Space or SpaceList Name 155.3169; !- Surface Area {m2} InternalMass, G SW Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name G SW Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, G NW Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name G NW Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, G NE Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name G NE Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, G N1 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name G N1 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, G N2 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name G N2 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, G S1 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name G S1 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, G S2 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name G S2 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M SW Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M SW Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M NW Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M NW Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M SE Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M SE Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M NE Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M NE Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M N1 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M N1 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M N2 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M N2 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M S1 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M S1 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, M S2 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name M S2 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T SW Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T SW Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T NW Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T NW Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T SE Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T SE Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T NE Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T NE Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T N1 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T N1 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T N2 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T N2 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T S1 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T S1 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} InternalMass, T S2 Apartment Internal Mass, !- Name InteriorFurnishings, !- Construction Name T S2 Apartment, !- Zone or ZoneList Name , !- Space or SpaceList Name 176.4974; !- Surface Area {m2} ! ***INTERNAL GAINS SCHEDULES*** SCHEDULE:COMPACT, BLDG_ELEVATORS, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 04:00,0.05, !- Field 3 Until: 05:00,0.10, !- Field 5 Until: 06:00,0.20, !- Field 7 Until: 07:00,0.40, !- Field 9 Until: 09:00,0.50, !- Field 11 Until: 10:00,0.35, !- Field 13 Until: 16:00,0.15, !- Field 15 Until: 17:00,0.35, !- Field 17 Until: 19:00,0.50, !- Field 19 Until: 21:00,0.40, !- Field 21 Until: 22:00,0.30, !- Field 23 Until: 23:00,0.20, !- Field 25 Until: 24:00,0.10; !- Field 27 Schedule:Compact, INFIL_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 Schedule:Compact, OFFICE_INFIL_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays, !- Field 2 Until: 8:00,1.0, !- Field 3 Until: 17:00,0.25, !- Field 5 Until: 24:00,1.0, !- Field 7 For AllOtherDays, !- Field 9 Until: 24:00,1.0; !- Field 10 Schedule:Compact, APT_OCC_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 7:00,1.0, !- Field 3 Until: 8:00,0.85, !- Field 5 Until: 9:00,0.39, !- Field 7 Until: 16:00,0.25, !- Field 9 Until: 17:00,0.3, !- Field 11 Until: 18:00,0.52, !- Field 13 Until: 21:00,0.87, !- Field 15 Until: 24:00,1.0; !- Field 17 Schedule:Compact, OFF_OCC_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay WinterDesignDay, !- Field 2 Until: 8:00,0.0, !- Field 3 Until: 12:00,1.0, !- Field 5 Until: 13:00,0.5, !- Field 7 Until: 17:00,1.0, !- Field 9 Until: 24:00,0.0, !- Field 11 For AllOtherDays, !- Field 13 Until: 24:00,0.0; !- Field 14 Schedule:Compact, APT_LIGHT_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 04:00,0.067, !- Field 3 Until: 05:00,0.187, !- Field 5 Until: 06:00,0.394, !- Field 7 Until: 07:00,0.440, !- Field 9 Until: 08:00,0.393, !- Field 11 Until: 09:00,0.172, !- Field 13 Until: 15:00,0.119, !- Field 15 Until: 16:00,0.206, !- Field 17 Until: 17:00,0.439, !- Field 19 Until: 18:00,0.616, !- Field 21 Until: 19:00,0.829, !- Field 23 Until: 20:00,0.986, !- Field 25 Until: 21:00,1.0, !- Field 27 Until: 22:00,0.692, !- Field 29 Until: 23:00,0.384, !- Field 31 Until: 24:00,0.160; !- Field 33 Schedule:Compact, OFF_LIGHT_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 08:00,0.18, !- Field 3 Until: 12:00,0.90, !- Field 5 Until: 13:00,0.80, !- Field 7 Until: 17:00,0.90, !- Field 9 Until: 24:00,0.18, !- Field 11 For: AllOtherDays, !- Field 13 Until: 24:00,0.18; !- Field 14 Schedule:Compact, COR_LIGHT_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0; !- Field 3 Schedule:Compact, APT_EQP_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 1:00,0.45, !- Field 3 Until: 2:00,0.41, !- Field 5 Until: 3:00,0.39, !- Field 7 Until: 5:00,0.38, !- Field 9 Until: 6:00,0.43, !- Field 11 Until: 7:00,0.54, !- Field 13 Until: 8:00,0.65, !- Field 15 Until: 9:00,0.66, !- Field 17 Until: 10:00,0.67, !- Field 19 Until: 11:00,0.69, !- Field 21 Until: 12:00,0.70, !- Field 23 Until: 13:00,0.69, !- Field 25 Until: 14:00,0.66, !- Field 27 Until: 15:00,0.65, !- Field 29 Until: 16:00,0.68, !- Field 31 Until: 17:00,0.80, !- Field 33 Until: 19:00,1.0, !- Field 35 Until: 20:00,0.93, !- Field 37 Until: 21:00,0.89, !- Field 39 Until: 22:00,0.85, !- Field 41 Until: 23:00,0.71, !- Field 43 Until: 24:00,0.58; !- Field 45 Schedule:Compact, OFF_EQP_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay, !- Field 2 Until: 7:00,0.33, !- Field 3 Until: 8:00,0.5, !- Field 5 Until: 12:00,1.0, !- Field 7 Until: 13:00,0.94, !- Field 9 Until: 17:00,1.0, !- Field 11 Until: 18:00,0.5, !- Field 13 Until: 24:00,0.33, !- Field 15 For AllOtherDays, !- Field 17 Until: 24:00,0.33; !- Field 18 Schedule:Compact, ACTIVITY_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,120; !- Field 3 Schedule:Compact, WORK_EFF_SCH, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.0; !- Field 3 Schedule:Compact, AIR_VELO_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, CLOTHING_SCH, !- Name Any Number, !- Schedule Type Limits Name Through: 04/30, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1.0, !- Field 3 Through: 09/30, !- Field 5 For: AllDays, !- Field 6 Until: 24:00,0.5, !- Field 7 Through: 12/31, !- Field 9 For: AllDays, !- Field 10 Until: 24:00,1.0; !- Field 11 ! ***HVAC EQUIPMENT*** Fan:OnOff, SPLITSYSTEMAC:01_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:01_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:01_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:02_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:02_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:02_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:03_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:03_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:03_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:04_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:04_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:04_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:05_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:05_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:05_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:06_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:06_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:06_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:07_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:07_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:07_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:08_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:08_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:08_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:09_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:09_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:09_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:10_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:10_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:10_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:11_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:11_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:11_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:12_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:12_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:12_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:13_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:13_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:13_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:14_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:14_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:14_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:15_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:15_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:15_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:16_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:16_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:16_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:17_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:17_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:17_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:18_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:18_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:18_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:19_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:19_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:19_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:20_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:20_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:20_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:21_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:21_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:21_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:22_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:22_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:22_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:23_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:23_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:23_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Fan:OnOff, SPLITSYSTEMAC:24_Unitary_Package_fan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 622.0, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction OA-SPLITSYSTEMAC:24_Unitary_PackageNode, !- Air Inlet Node Name SPLITSYSTEMAC:24_Unitary_PackageCoolCoil air inlet, !- Air Outlet Node Name , !- Fan Power Ratio Function of Speed Ratio Curve Name , !- Fan Efficiency Ratio Function of Speed Ratio Curve Name Unitary Fans; !- End-Use Subcategory Coil:Heating:Fuel, SPLITSYSTEMAC:01_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:01_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:01 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:02_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:02_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:02 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:03_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:03_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:03 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:04_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:04_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:04 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:05_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:05_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:05 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:06_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:06_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:06 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:07_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:07_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:07 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:08_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:08_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:08 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:09_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:09_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:09 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:10_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:10_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:10 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:11_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:11_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:11 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:12_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:12_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:12 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:13_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:13_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:13 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:14_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:14_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:14 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:15_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:15_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:15 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:16_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:16_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:16 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:17_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:17_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:17 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:18_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:18_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:18 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:19_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:19_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:19 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:20_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:20_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:20 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:21_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:21_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:21 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:22_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:22_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:22 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:23_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:23_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:23 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Heating:Fuel, SPLITSYSTEMAC:24_Unitary_Package_HeatCoil, !- Name ALWAYS_ON, !- Availability Schedule Name NaturalGas, !- Fuel Type 0.8, !- Burner Efficiency AUTOSIZE, !- Nominal Capacity {W} SPLITSYSTEMAC:24_Unitary_PackageHeatCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:24 Supply Equipment Outlet Node; !- Air Outlet Node Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:01_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:01_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:01_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:02_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:02_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:02_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:03_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:03_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:03_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:04_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:04_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:04_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:05_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:05_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:05_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:06_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:06_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:06_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:07_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:07_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:07_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:08_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:08_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:08_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:09_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:09_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:09_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:10_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:10_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:10_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:11_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:11_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:11_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:12_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:12_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:12_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:13_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:13_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:13_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:14_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:14_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:14_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:15_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:15_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:15_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:16_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:16_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:16_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:17_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:17_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:17_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:18_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:18_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:18_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:19_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:19_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:19_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:20_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:20_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:20_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:21_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:21_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:21_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:22_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:22_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:22_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:23_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:23_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:23_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name Coil:Cooling:DX:SingleSpeed, SPLITSYSTEMAC:24_Unitary_Package_CoolCoil, !- Name ALWAYS_ON, !- Availability Schedule Name AUTOSIZE, !- Gross Rated Total Cooling Capacity {W} AUTOSIZE, !- Gross Rated Sensible Heat Ratio 3.66668442928701, !- Gross Rated Cooling COP {W/W} AUTOSIZE, !- Rated Air Flow Rate {m3/s} , !- Rated Evaporator Fan Power Per Volume Flow Rate {W/(m3/s)} 934.4, !- 2023 Rated Evaporator Fan Power Per Volume Flow {W/(m3/s)} SPLITSYSTEMAC:24_Unitary_PackageCoolCoil air inlet, !- Air Inlet Node Name SPLITSYSTEMAC:24_Unitary_PackageHeatCoil air inlet, !- Air Outlet Node Name Cool-Cap-fT, !- Total Cooling Capacity Function of Temperature Curve Name ConstantCubic, !- Total Cooling Capacity Function of Flow Fraction Curve Name Cool-EIR-fT, !- Energy Input Ratio Function of Temperature Curve Name ConstantCubic, !- Energy Input Ratio Function of Flow Fraction Curve Name Cool-PLF-fPLR; !- Part Load Fraction Correlation Curve Name ZoneHVAC:UnitHeater, G Corridor Unit Heater, !- Name ALWAYS_ON, !- Availability Schedule Name G Corridor Unit Heater Exhaust Node, !- Air Inlet Node Name G Corridor Unit Heater Inlet Node Name, !- Air Outlet Node Name Fan:ConstantVolume, !- Supply Air Fan Object Type G Corridor Unit HeaterFan, !- Supply Air Fan Name AUTOSIZE, !- Maximum Supply Air Flow Rate {m3/s} Coil:Heating:Electric, !- Heating Coil Object Type G Corridor Unit Heater coil, !- Heating Coil Name , !- Supply Air Fan Operating Mode Schedule Name No, !- Supply Air Fan Operation During No Heating AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} 0.001; !- Heating Convergence Tolerance ZoneHVAC:UnitHeater, M Corridor Unit Heater, !- Name ALWAYS_ON, !- Availability Schedule Name M Corridor Unit Heater Exhaust Node, !- Air Inlet Node Name M Corridor Unit Heater Inlet Node Name, !- Air Outlet Node Name Fan:ConstantVolume, !- Supply Air Fan Object Type M Corridor Unit HeaterFan, !- Supply Air Fan Name AUTOSIZE, !- Maximum Supply Air Flow Rate {m3/s} Coil:Heating:Electric, !- Heating Coil Object Type M Corridor Unit Heater coil, !- Heating Coil Name , !- Supply Air Fan Operating Mode Schedule Name No, !- Supply Air Fan Operation During No Heating AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} 0.001; !- Heating Convergence Tolerance ZoneHVAC:UnitHeater, T Corridor Unit Heater, !- Name ALWAYS_ON, !- Availability Schedule Name T Corridor Unit Heater Exhaust Node, !- Air Inlet Node Name T Corridor Unit Heater Inlet Node Name, !- Air Outlet Node Name Fan:ConstantVolume, !- Supply Air Fan Object Type T Corridor Unit HeaterFan, !- Supply Air Fan Name AUTOSIZE, !- Maximum Supply Air Flow Rate {m3/s} Coil:Heating:Electric, !- Heating Coil Object Type T Corridor Unit Heater coil, !- Heating Coil Name , !- Supply Air Fan Operating Mode Schedule Name No, !- Supply Air Fan Operation During No Heating AUTOSIZE, !- Maximum Hot Water or Steam Flow Rate {m3/s} 0.0, !- Minimum Hot Water or Steam Flow Rate {m3/s} 0.001; !- Heating Convergence Tolerance Coil:Heating:Electric, G Corridor Unit Heater coil, !- Name ALWAYS_ON, !- Availability Schedule Name 1.0, !- Efficiency AUTOSIZE, !- Nominal Capacity {W} G Corridor Unit Heater Post Fan Node, !- Air Inlet Node Name G Corridor Unit Heater Inlet Node Name; !- Air Outlet Node Name Coil:Heating:Electric, M Corridor Unit Heater coil, !- Name ALWAYS_ON, !- Availability Schedule Name 1.0, !- Efficiency AUTOSIZE, !- Nominal Capacity {W} M Corridor Unit Heater Post Fan Node, !- Air Inlet Node Name M Corridor Unit Heater Inlet Node Name; !- Air Outlet Node Name Coil:Heating:Electric, T Corridor Unit Heater coil, !- Name ALWAYS_ON, !- Availability Schedule Name 1.0, !- Efficiency AUTOSIZE, !- Nominal Capacity {W} T Corridor Unit Heater Post Fan Node, !- Air Inlet Node Name T Corridor Unit Heater Inlet Node Name; !- Air Outlet Node Name Fan:ConstantVolume, G Corridor Unit HeaterFan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 49.8, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction G Corridor Unit Heater Exhaust Node, !- Air Inlet Node Name G Corridor Unit Heater Post Fan Node, !- Air Outlet Node Name Unit Heater Fans; !- End-Use Subcategory Fan:ConstantVolume, M Corridor Unit HeaterFan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 49.8, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction M Corridor Unit Heater Exhaust Node, !- Air Inlet Node Name M Corridor Unit Heater Post Fan Node, !- Air Outlet Node Name Unit Heater Fans; !- End-Use Subcategory Fan:ConstantVolume, T Corridor Unit HeaterFan, !- Name ALWAYS_ON, !- Availability Schedule Name 0.53625, !- Fan Total Efficiency 49.8, !- Pressure Rise {Pa} AUTOSIZE, !- Maximum Flow Rate {m3/s} 0.825, !- Motor Efficiency 1.0, !- Motor In Airstream Fraction T Corridor Unit Heater Exhaust Node, !- Air Inlet Node Name T Corridor Unit Heater Post Fan Node, !- Air Outlet Node Name Unit Heater Fans; !- End-Use Subcategory ZoneHVAC:EquipmentList, G Corridor Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:UnitHeater, !- Zone Equipment 1 Object Type G Corridor Unit Heater, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, G N1 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type G N1 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, G N2 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type G N2 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, G NE Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type G NE Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, G NW Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type G NW Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, G S1 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type G S1 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, G S2 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type G S2 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, G SW Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type G SW Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M Corridor Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:UnitHeater, !- Zone Equipment 1 Object Type M Corridor Unit Heater, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M N1 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M N1 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M N2 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M N2 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M NE Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M NE Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M NW Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M NW Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M S1 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M S1 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M S2 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M S2 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M SE Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M SE Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, M SW Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type M SW Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, Office Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type Office Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T Corridor Equipment, !- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:UnitHeater, !- Zone Equipment 1 Object Type T Corridor Unit Heater, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T N1 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T N1 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T N2 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T N2 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T NE Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T NE Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T NW Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T NW Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T S1 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T S1 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T S2 Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T S2 Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T SE Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T SE Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ZoneHVAC:EquipmentList, T SW Apartment Equipment,!- Name SequentialLoad, !- Load Distribution Scheme ZoneHVAC:AirDistributionUnit, !- Zone Equipment 1 Object Type T SW Apartment Direct Air ADU, !- Zone Equipment 1 Name 1, !- Zone Equipment 1 Cooling Sequence 1, !- Zone Equipment 1 Heating or No-Load Sequence , !- Zone Equipment 1 Sequential Cooling Fraction Schedule Name ; !- Zone Equipment 1 Sequential Heating Fraction Schedule Name ! ***SIZING & CONTROLS*** Sizing:Zone, G Corridor, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G Corridor, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G Corridor, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, G N1 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G N1 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G N1 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, G N2 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G N2 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G N2 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, G NE Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G NE Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G NE Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, G NW Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G NW Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G NW Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, G S1 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G S1 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G S1 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, G S2 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G S2 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G S2 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, G SW Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA G SW Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA G SW Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M Corridor, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M Corridor, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M Corridor, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M N1 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M N1 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M N1 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M N2 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M N2 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M N2 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M NE Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M NE Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M NE Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M NW Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M NW Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M NW Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M S1 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M S1 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M S1 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M S2 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M S2 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M S2 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M SE Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M SE Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M SE Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, M SW Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 14.0000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA M SW Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA M SW Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, Office, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA Office, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA Office, !- Name Flow/Person, !- Outdoor Air Method 0.01, !- Outdoor Air Flow per Person {m3/s-person} , !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} ; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T Corridor, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T Corridor, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T Corridor, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T N1 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T N1 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T N1 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T N2 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T N2 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T N2 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T NE Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T NE Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T NE Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T NW Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T NW Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T NW Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T S1 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T S1 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T S1 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T S2 Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T S2 Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T S2 Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T SE Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 11.1000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T SE Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T SE Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} Sizing:Zone, T SW Apartment, !- Zone or ZoneList Name SupplyAirTemperature, !- Zone Cooling Design Supply Air Temperature Input Method 14.0000, !- Zone Cooling Design Supply Air Temperature {C} , !- Zone Cooling Design Supply Air Temperature Difference {deltaC} SupplyAirTemperature, !- Zone Heating Design Supply Air Temperature Input Method 40.0000, !- Zone Heating Design Supply Air Temperature {C} , !- Zone Heating Design Supply Air Temperature Difference {deltaC} 0.0085, !- Zone Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Zone Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} SZ DSOA T SW Apartment, !- Design Specification Outdoor Air Object Name , !- Zone Heating Sizing Factor , !- Zone Cooling Sizing Factor DesignDayWithLimit, !- Cooling Design Air Flow Method , !- Cooling Design Air Flow Rate {m3/s} , !- Cooling Minimum Air Flow per Zone Floor Area {m3/s-m2} 0, !- Cooling Minimum Air Flow {m3/s} 0.0, !- Cooling Minimum Air Flow Fraction DesignDay, !- Heating Design Air Flow Method 0.0, !- Heating Design Air Flow Rate {m3/s} , !- Heating Maximum Air Flow per Zone Floor Area {m3/s-m2} , !- Heating Maximum Air Flow {m3/s} , !- Heating Maximum Air Flow Fraction , !- Design Specification Zone Air Distribution Object Name No, !- Account for Dedicated Outdoor Air System NeutralSupplyAir, !- Dedicated Outdoor Air System Control Strategy autosize, !- Dedicated Outdoor Air Low Setpoint Temperature for Design {C} autosize; !- Dedicated Outdoor Air High Setpoint Temperature for Design {C} DesignSpecification:OutdoorAir, SZ DSOA T SW Apartment, !- Name Flow/Zone, !- Outdoor Air Method 0.0, !- Outdoor Air Flow per Person {m3/s-person} 0.0, !- Outdoor Air Flow per Zone Floor Area {m3/s-m2} 0.04248; !- Outdoor Air Flow per Zone {m3/s} ZoneControl:Thermostat, G Corridor Thermostat, !- Name G Corridor, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G Corridor DualSPSched; !- Control 1 Name ZoneControl:Thermostat, G N1 Apartment Thermostat, !- Name G N1 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G N1 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, G N2 Apartment Thermostat, !- Name G N2 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G N2 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, G NE Apartment Thermostat, !- Name G NE Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G NE Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, G NW Apartment Thermostat, !- Name G NW Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G NW Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, G S1 Apartment Thermostat, !- Name G S1 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G S1 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, G S2 Apartment Thermostat, !- Name G S2 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G S2 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, G SW Apartment Thermostat, !- Name G SW Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type G SW Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M Corridor Thermostat, !- Name M Corridor, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M Corridor DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M N1 Apartment Thermostat, !- Name M N1 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M N1 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M N2 Apartment Thermostat, !- Name M N2 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M N2 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M NE Apartment Thermostat, !- Name M NE Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M NE Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M NW Apartment Thermostat, !- Name M NW Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M NW Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M S1 Apartment Thermostat, !- Name M S1 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M S1 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M S2 Apartment Thermostat, !- Name M S2 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M S2 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M SE Apartment Thermostat, !- Name M SE Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M SE Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, M SW Apartment Thermostat, !- Name M SW Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type M SW Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, Office Thermostat, !- Name Office, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type Office DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T Corridor Thermostat, !- Name T Corridor, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T Corridor DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T N1 Apartment Thermostat, !- Name T N1 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T N1 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T N2 Apartment Thermostat, !- Name T N2 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T N2 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T NE Apartment Thermostat, !- Name T NE Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T NE Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T NW Apartment Thermostat, !- Name T NW Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T NW Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T S1 Apartment Thermostat, !- Name T S1 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T S1 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T S2 Apartment Thermostat, !- Name T S2 Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T S2 Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T SE Apartment Thermostat, !- Name T SE Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T SE Apartment DualSPSched; !- Control 1 Name ZoneControl:Thermostat, T SW Apartment Thermostat, !- Name T SW Apartment, !- Zone or ZoneList Name Dual Zone Control Type Sched, !- Control Type Schedule Name ThermostatSetpoint:DualSetpoint, !- Control 1 Object Type T SW Apartment DualSPSched; !- Control 1 Name ThermostatSetpoint:DualSetpoint, G Corridor DualSPSched, !- Name UnitHeater_HtgSP_Sch, !- Heating Setpoint Temperature Schedule Name UnitHeater_ClgSP_Sch; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, G N1 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, G N2 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, G NE Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, G NW Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, G S1 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, G S2 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, G SW Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M Corridor DualSPSched, !- Name UnitHeater_HtgSP_Sch, !- Heating Setpoint Temperature Schedule Name UnitHeater_ClgSP_Sch; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M N1 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M N2 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M NE Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M NW Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M S1 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M S2 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M SE Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, M SW Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, Office DualSPSched, !- Name OFF_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name OFF_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T Corridor DualSPSched, !- Name UnitHeater_HtgSP_Sch, !- Heating Setpoint Temperature Schedule Name UnitHeater_ClgSP_Sch; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T N1 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T N2 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T NE Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T NW Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T S1 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T S2 Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T SE Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name ThermostatSetpoint:DualSetpoint, T SW Apartment DualSPSched, !- Name APT_HTGSETP_SCH, !- Heating Setpoint Temperature Schedule Name APT_CLGSETP_SCH; !- Cooling Setpoint Temperature Schedule Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr G N1 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} G N1 Apartment, !- Control Zone Name G N1 Apartment Air Node, !- Zone Node Name G N1 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:05 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr G N2 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} G N2 Apartment, !- Control Zone Name G N2 Apartment Air Node, !- Zone Node Name G N2 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:06 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr G NE Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} G NE Apartment, !- Control Zone Name G NE Apartment Air Node, !- Zone Node Name G NE Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:04 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr G NW Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} G NW Apartment, !- Control Zone Name G NW Apartment Air Node, !- Zone Node Name G NW Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:02 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr G S1 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} G S1 Apartment, !- Control Zone Name G S1 Apartment Air Node, !- Zone Node Name G S1 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:07 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr G S2 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} G S2 Apartment, !- Control Zone Name G S2 Apartment Air Node, !- Zone Node Name G S2 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:08 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr G SW Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} G SW Apartment, !- Control Zone Name G SW Apartment Air Node, !- Zone Node Name G SW Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:01 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M N1 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M N1 Apartment, !- Control Zone Name M N1 Apartment Air Node, !- Zone Node Name M N1 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:13 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M N2 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M N2 Apartment, !- Control Zone Name M N2 Apartment Air Node, !- Zone Node Name M N2 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:14 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M NE Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M NE Apartment, !- Control Zone Name M NE Apartment Air Node, !- Zone Node Name M NE Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:12 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M NW Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M NW Apartment, !- Control Zone Name M NW Apartment Air Node, !- Zone Node Name M NW Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:10 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M S1 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M S1 Apartment, !- Control Zone Name M S1 Apartment Air Node, !- Zone Node Name M S1 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:15 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M S2 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M S2 Apartment, !- Control Zone Name M S2 Apartment Air Node, !- Zone Node Name M S2 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:16 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M SE Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M SE Apartment, !- Control Zone Name M SE Apartment Air Node, !- Zone Node Name M SE Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:11 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr M SW Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} M SW Apartment, !- Control Zone Name M SW Apartment Air Node, !- Zone Node Name M SW Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:09 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T N1 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T N1 Apartment, !- Control Zone Name T N1 Apartment Air Node, !- Zone Node Name T N1 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:21 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T N2 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T N2 Apartment, !- Control Zone Name T N2 Apartment Air Node, !- Zone Node Name T N2 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:22 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T NE Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T NE Apartment, !- Control Zone Name T NE Apartment Air Node, !- Zone Node Name T NE Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:20 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T NW Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T NW Apartment, !- Control Zone Name T NW Apartment Air Node, !- Zone Node Name T NW Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:18 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T S1 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T S1 Apartment, !- Control Zone Name T S1 Apartment Air Node, !- Zone Node Name T S1 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:23 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T S2 Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T S2 Apartment, !- Control Zone Name T S2 Apartment Air Node, !- Zone Node Name T S2 Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:24 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T SE Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T SE Apartment, !- Control Zone Name T SE Apartment Air Node, !- Zone Node Name T SE Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:19 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp Mngr T SW Apartment, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} T SW Apartment, !- Control Zone Name T SW Apartment Air Node, !- Zone Node Name T SW Apartment Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:17 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name SetpointManager:SingleZone:Reheat, SupAirTemp MngrOffice, !- Name Temperature, !- Control Variable 10.0, !- Minimum Supply Air Temperature {C} 50.0, !- Maximum Supply Air Temperature {C} Office, !- Control Zone Name Office Air Node, !- Zone Node Name Office Direct Air Inlet Node Name, !- Zone Inlet Node Name SPLITSYSTEMAC:03 Supply Equipment Outlet Node; !- Setpoint Node or NodeList Name Sizing:System, SPLITSYSTEMAC:01, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:02, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:03, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:04, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:05, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:06, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:07, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:08, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:09, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:10, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:11, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:12, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:13, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:14, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:15, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:16, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:17, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:18, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:19, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:20, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:21, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:22, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:23, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Sizing:System, SPLITSYSTEMAC:24, !- AirLoop Name Sensible, !- Type of Load to Size On AUTOSIZE, !- Design Outdoor Air Flow Rate {m3/s} 1.0000, !- Central Heating Maximum System Air Flow Ratio 7.0, !- Preheat Design Temperature {C} 0.008, !- Preheat Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Precool Design Temperature {C} 0.008, !- Precool Design Humidity Ratio {kgWater/kgDryAir} 11.1000, !- Central Cooling Design Supply Air Temperature {C} 40.0, !- Central Heating Design Supply Air Temperature {C} NonCoincident, !- Type of Zone Sum to Use No, !- 100% Outdoor Air in Cooling No, !- 100% Outdoor Air in Heating 0.0085, !- Central Cooling Design Supply Air Humidity Ratio {kgWater/kgDryAir} 0.0080, !- Central Heating Design Supply Air Humidity Ratio {kgWater/kgDryAir} DesignDay, !- Cooling Supply Air Flow Rate Method 0.0, !- Cooling Supply Air Flow Rate {m3/s} , !- Cooling Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Cooling Fraction of Autosized Cooling Supply Air Flow Rate , !- Cooling Supply Air Flow Rate Per Unit Cooling Capacity {m3/s-W} DesignDay, !- Heating Supply Air Flow Rate Method 0.0, !- Heating Supply Air Flow Rate {m3/s} , !- Heating Supply Air Flow Rate Per Floor Area {m3/s-m2} , !- Heating Fraction of Autosized Heating Supply Air Flow Rate , !- Heating Fraction of Autosized Cooling Supply Air Flow Rate , !- Heating Supply Air Flow Rate Per Unit Heating Capacity {m3/s-W} , !- System Outdoor Air Method 1.0, !- Zone Maximum Outdoor Air Fraction {dimensionless} CoolingDesignCapacity, !- Cooling Design Capacity Method autosize, !- Cooling Design Capacity {W} , !- Cooling Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Cooling Design Capacity HeatingDesignCapacity, !- Heating Design Capacity Method autosize, !- Heating Design Capacity {W} , !- Heating Design Capacity Per Floor Area {W/m2} , !- Fraction of Autosized Heating Design Capacity VAV; !- Central Cooling Capacity Control Method Controller:OutdoorAir, SPLITSYSTEMAC:01_OA_Controller, !- Name SPLITSYSTEMAC:01_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:01 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:01_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:01_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:02_OA_Controller, !- Name SPLITSYSTEMAC:02_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:02 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:02_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:02_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:03_OA_Controller, !- Name SPLITSYSTEMAC:03_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:03 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:03_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:03_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type Office_Operation, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:04_OA_Controller, !- Name SPLITSYSTEMAC:04_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:04 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:04_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:04_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:05_OA_Controller, !- Name SPLITSYSTEMAC:05_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:05 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:05_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:05_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:06_OA_Controller, !- Name SPLITSYSTEMAC:06_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:06 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:06_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:06_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:07_OA_Controller, !- Name SPLITSYSTEMAC:07_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:07 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:07_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:07_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:08_OA_Controller, !- Name SPLITSYSTEMAC:08_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:08 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:08_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:08_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:09_OA_Controller, !- Name SPLITSYSTEMAC:09_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:09 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:09_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:09_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:10_OA_Controller, !- Name SPLITSYSTEMAC:10_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:10 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:10_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:10_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:11_OA_Controller, !- Name SPLITSYSTEMAC:11_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:11 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:11_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:11_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:12_OA_Controller, !- Name SPLITSYSTEMAC:12_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:12 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:12_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:12_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:13_OA_Controller, !- Name SPLITSYSTEMAC:13_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:13 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:13_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:13_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:14_OA_Controller, !- Name SPLITSYSTEMAC:14_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:14 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:14_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:14_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:15_OA_Controller, !- Name SPLITSYSTEMAC:15_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:15 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:15_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:15_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:16_OA_Controller, !- Name SPLITSYSTEMAC:16_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:16 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:16_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:16_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:17_OA_Controller, !- Name SPLITSYSTEMAC:17_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:17 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:17_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:17_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:18_OA_Controller, !- Name SPLITSYSTEMAC:18_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:18 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:18_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:18_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:19_OA_Controller, !- Name SPLITSYSTEMAC:19_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:19 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:19_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:19_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:20_OA_Controller, !- Name SPLITSYSTEMAC:20_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:20 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:20_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:20_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:21_OA_Controller, !- Name SPLITSYSTEMAC:21_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:21 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:21_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:21_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:22_OA_Controller, !- Name SPLITSYSTEMAC:22_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:22 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:22_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:22_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:23_OA_Controller, !- Name SPLITSYSTEMAC:23_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:23 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:23_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:23_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Controller:OutdoorAir, SPLITSYSTEMAC:24_OA_Controller, !- Name SPLITSYSTEMAC:24_OARelief Node, !- Relief Air Outlet Node Name SPLITSYSTEMAC:24 Supply Equipment Inlet Node, !- Return Air Node Name OA-SPLITSYSTEMAC:24_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:24_OAInlet Node, !- Actuator Node Name AUTOSIZE, !- Minimum Outdoor Air Flow Rate {m3/s} AUTOSIZE, !- Maximum Outdoor Air Flow Rate {m3/s} NoEconomizer, !- Economizer Control Type ModulateFlow, !- Economizer Control Action Type 28.0, !- Economizer Maximum Limit Dry-Bulb Temperature {C} 64000.0, !- Economizer Maximum Limit Enthalpy {J/kg} , !- Economizer Maximum Limit Dewpoint Temperature {C} , !- Electronic Enthalpy Limit Curve Name -100.0, !- Economizer Minimum Limit Dry-Bulb Temperature {C} NoLockout, !- Lockout Type FixedMinimum, !- Minimum Limit Type MinOA_Sched, !- Minimum Outdoor Air Schedule Name , !- Minimum Fraction of Outdoor Air Schedule Name , !- Maximum Fraction of Outdoor Air Schedule Name ; !- Mechanical Ventilation Controller Name Curve:Quadratic, Cool-PLF-fPLR, !- Name 0.90949556, !- Coefficient1 Constant 0.09864773, !- Coefficient2 x -0.00819488, !- Coefficient3 x**2 0, !- Minimum Value of x 1, !- Maximum Value of x 0.7, !- Minimum Curve Output 1; !- Maximum Curve Output Curve:Cubic, ConstantCubic, !- Name 1, !- Coefficient1 Constant 0, !- Coefficient2 x 0, !- Coefficient3 x**2 0, !- Coefficient4 x**3 -100, !- Minimum Value of x 100; !- Maximum Value of x Curve:Biquadratic, Cool-Cap-fT, !- Name 0.9712123, !- Coefficient1 Constant -0.015275502, !- Coefficient2 x 0.0014434524, !- Coefficient3 x**2 -0.00039321, !- Coefficient4 y -0.0000068364, !- Coefficient5 y**2 -0.0002905956, !- Coefficient6 x*y -100, !- Minimum Value of x 100, !- Maximum Value of x -100, !- Minimum Value of y 100; !- Maximum Value of y Curve:Biquadratic, Cool-EIR-fT, !- Name 0.28687133, !- Coefficient1 Constant 0.023902164, !- Coefficient2 x -0.000810648, !- Coefficient3 x**2 0.013458546, !- Coefficient4 y 0.0003389364, !- Coefficient5 y**2 -0.0004870044, !- Coefficient6 x*y -100, !- Minimum Value of x 100, !- Maximum Value of x -100, !- Minimum Value of y 100; !- Maximum Value of y ! ***AIR LOOPS*** AirLoopHVAC, SPLITSYSTEMAC:01, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:01 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:01 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:01 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:01 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:01 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:10, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:10 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:10 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:10 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:10 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:10 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:11, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:11 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:11 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:11 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:11 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:11 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:12, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:12 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:12 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:12 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:12 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:12 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:13, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:13 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:13 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:13 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:13 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:13 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:14, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:14 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:14 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:14 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:14 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:14 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:15, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:15 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:15 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:15 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:15 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:15 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:16, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:16 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:16 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:16 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:16 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:16 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:17, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:17 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:17 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:17 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:17 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:17 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:18, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:18 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:18 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:18 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:18 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:18 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:19, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:19 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:19 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:19 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:19 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:19 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:02, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:02 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:02 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:02 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:02 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:02 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:20, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:20 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:20 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:20 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:20 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:20 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:21, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:21 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:21 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:21 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:21 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:21 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:22, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:22 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:22 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:22 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:22 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:22 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:23, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:23 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:23 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:23 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:23 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:23 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:24, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:24 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:24 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:24 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:24 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:24 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:03, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:03 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:03 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:03 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:03 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:03 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:04, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:04 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:04 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:04 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:04 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:04 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:05, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:05 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:05 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:05 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:05 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:05 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:06, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:06 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:06 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:06 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:06 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:06 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:07, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:07 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:07 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:07 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:07 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:07 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:08, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:08 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:08 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:08 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:08 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:08 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC, SPLITSYSTEMAC:09, !- Name , !- Controller List Name , !- Availability Manager List Name AUTOSIZE, !- Design Supply Air Flow Rate {m3/s} SPLITSYSTEMAC:09 Air Loop Branches, !- Branch List Name , !- Connector List Name SPLITSYSTEMAC:09 Supply Equipment Inlet Node, !- Supply Side Inlet Node Name SPLITSYSTEMAC:09 Zone Equipment Outlet Node, !- Demand Side Outlet Node Name SPLITSYSTEMAC:09 Zone Equipment Inlet Node, !- Demand Side Inlet Node Names SPLITSYSTEMAC:09 Supply Equipment Outlet Node; !- Supply Side Outlet Node Names AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:01_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:01_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:01 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} G SW Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:01_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:01_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:01_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:02_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:02_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:02 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} G NW Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:02_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:02_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:02_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:03_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:03_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:03 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Office_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} Office, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:03_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:03_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:03_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:04_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:04_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:04 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} G NE Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:04_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:04_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:04_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:05_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:05_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:05 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} G N1 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:05_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:05_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:05_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:06_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:06_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:06 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} G N2 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:06_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:06_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:06_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:07_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:07_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:07 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} G S1 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:07_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:07_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:07_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:08_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:08_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:08 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} G S2 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:08_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:08_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:08_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:09_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:09_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:09 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M SW Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:09_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:09_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:09_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:10_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:10_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:10 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M NW Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:10_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:10_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:10_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:11_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:11_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:11 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M SE Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:11_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:11_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:11_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:12_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:12_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:12 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M NE Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:12_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:12_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:12_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:13_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:13_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:13 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M N1 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:13_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:13_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:13_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:14_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:14_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:14 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M N2 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:14_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:14_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:14_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:15_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:15_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:15 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M S1 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:15_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:15_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:15_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:16_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:16_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:16 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} M S2 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:16_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:16_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:16_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:17_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:17_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:17 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T SW Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:17_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:17_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:17_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:18_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:18_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:18 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T NW Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:18_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:18_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:18_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:19_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:19_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:19 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T SE Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:19_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:19_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:19_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:20_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:20_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:20 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T NE Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:20_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:20_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:20_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:21_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:21_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:21 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T N1 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:21_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:21_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:21_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:22_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:22_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:22 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T N2 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:22_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:22_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:22_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:23_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:23_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:23 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T S1 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:23_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:23_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:23_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name AirLoopHVAC:UnitaryHeatCool, SPLITSYSTEMAC:24_Unitary_Package, !- Name ALWAYS_ON, !- Availability Schedule Name OA-SPLITSYSTEMAC:24_Unitary_PackageNode, !- Unitary System Air Inlet Node Name SPLITSYSTEMAC:24 Supply Equipment Outlet Node, !- Unitary System Air Outlet Node Name Apt_Operation, !- Supply Air Fan Operating Mode Schedule Name AUTOSIZE, !- Maximum Supply Air Temperature {C} AUTOSIZE, !- Cooling Supply Air Flow Rate {m3/s} AUTOSIZE, !- Heating Supply Air Flow Rate {m3/s} AUTOSIZE, !- No Load Supply Air Flow Rate {m3/s} T S2 Apartment, !- Controlling Zone or Thermostat Location Fan:OnOff, !- Supply Fan Object Type SPLITSYSTEMAC:24_Unitary_Package_fan, !- Supply Fan Name BlowThrough, !- Fan Placement Coil:Heating:Fuel, !- Heating Coil Object Type SPLITSYSTEMAC:24_Unitary_Package_HeatCoil, !- Heating Coil Name Coil:Cooling:DX:SingleSpeed, !- Cooling Coil Object Type SPLITSYSTEMAC:24_Unitary_Package_CoolCoil, !- Cooling Coil Name None, !- Dehumidification Control Type , !- Reheat Coil Object Type ; !- Reheat Coil Name ! ***CONNECTIONS*** ZoneHVAC:EquipmentConnections, G Corridor, !- Zone Name G Corridor Equipment, !- Zone Conditioning Equipment List Name G Corridor Inlet Nodes, !- Zone Air Inlet Node or NodeList Name G Corridor Exhaust Nodes,!- Zone Air Exhaust Node or NodeList Name G Corridor Air Node, !- Zone Air Node Name G Corridor Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, G N1 Apartment, !- Zone Name G N1 Apartment Equipment,!- Zone Conditioning Equipment List Name G N1 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name G N1 Apartment Air Node, !- Zone Air Node Name G N1 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, G N2 Apartment, !- Zone Name G N2 Apartment Equipment,!- Zone Conditioning Equipment List Name G N2 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name G N2 Apartment Air Node, !- Zone Air Node Name G N2 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, G NE Apartment, !- Zone Name G NE Apartment Equipment,!- Zone Conditioning Equipment List Name G NE Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name G NE Apartment Air Node, !- Zone Air Node Name G NE Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, G NW Apartment, !- Zone Name G NW Apartment Equipment,!- Zone Conditioning Equipment List Name G NW Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name G NW Apartment Air Node, !- Zone Air Node Name G NW Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, G S1 Apartment, !- Zone Name G S1 Apartment Equipment,!- Zone Conditioning Equipment List Name G S1 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name G S1 Apartment Air Node, !- Zone Air Node Name G S1 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, G S2 Apartment, !- Zone Name G S2 Apartment Equipment,!- Zone Conditioning Equipment List Name G S2 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name G S2 Apartment Air Node, !- Zone Air Node Name G S2 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, G SW Apartment, !- Zone Name G SW Apartment Equipment,!- Zone Conditioning Equipment List Name G SW Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name G SW Apartment Air Node, !- Zone Air Node Name G SW Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M Corridor, !- Zone Name M Corridor Equipment, !- Zone Conditioning Equipment List Name M Corridor Inlet Nodes, !- Zone Air Inlet Node or NodeList Name M Corridor Exhaust Nodes,!- Zone Air Exhaust Node or NodeList Name M Corridor Air Node, !- Zone Air Node Name M Corridor Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M N1 Apartment, !- Zone Name M N1 Apartment Equipment,!- Zone Conditioning Equipment List Name M N1 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M N1 Apartment Air Node, !- Zone Air Node Name M N1 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M N2 Apartment, !- Zone Name M N2 Apartment Equipment,!- Zone Conditioning Equipment List Name M N2 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M N2 Apartment Air Node, !- Zone Air Node Name M N2 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M NE Apartment, !- Zone Name M NE Apartment Equipment,!- Zone Conditioning Equipment List Name M NE Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M NE Apartment Air Node, !- Zone Air Node Name M NE Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M NW Apartment, !- Zone Name M NW Apartment Equipment,!- Zone Conditioning Equipment List Name M NW Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M NW Apartment Air Node, !- Zone Air Node Name M NW Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M S1 Apartment, !- Zone Name M S1 Apartment Equipment,!- Zone Conditioning Equipment List Name M S1 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M S1 Apartment Air Node, !- Zone Air Node Name M S1 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M S2 Apartment, !- Zone Name M S2 Apartment Equipment,!- Zone Conditioning Equipment List Name M S2 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M S2 Apartment Air Node, !- Zone Air Node Name M S2 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M SE Apartment, !- Zone Name M SE Apartment Equipment,!- Zone Conditioning Equipment List Name M SE Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M SE Apartment Air Node, !- Zone Air Node Name M SE Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, M SW Apartment, !- Zone Name M SW Apartment Equipment,!- Zone Conditioning Equipment List Name M SW Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name M SW Apartment Air Node, !- Zone Air Node Name M SW Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, Office, !- Zone Name Office Equipment, !- Zone Conditioning Equipment List Name Office Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name Office Air Node, !- Zone Air Node Name Office Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T Corridor, !- Zone Name T Corridor Equipment, !- Zone Conditioning Equipment List Name T Corridor Inlet Nodes, !- Zone Air Inlet Node or NodeList Name T Corridor Exhaust Nodes,!- Zone Air Exhaust Node or NodeList Name T Corridor Air Node, !- Zone Air Node Name T Corridor Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T N1 Apartment, !- Zone Name T N1 Apartment Equipment,!- Zone Conditioning Equipment List Name T N1 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T N1 Apartment Air Node, !- Zone Air Node Name T N1 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T N2 Apartment, !- Zone Name T N2 Apartment Equipment,!- Zone Conditioning Equipment List Name T N2 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T N2 Apartment Air Node, !- Zone Air Node Name T N2 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T NE Apartment, !- Zone Name T NE Apartment Equipment,!- Zone Conditioning Equipment List Name T NE Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T NE Apartment Air Node, !- Zone Air Node Name T NE Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T NW Apartment, !- Zone Name T NW Apartment Equipment,!- Zone Conditioning Equipment List Name T NW Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T NW Apartment Air Node, !- Zone Air Node Name T NW Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T S1 Apartment, !- Zone Name T S1 Apartment Equipment,!- Zone Conditioning Equipment List Name T S1 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T S1 Apartment Air Node, !- Zone Air Node Name T S1 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T S2 Apartment, !- Zone Name T S2 Apartment Equipment,!- Zone Conditioning Equipment List Name T S2 Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T S2 Apartment Air Node, !- Zone Air Node Name T S2 Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T SE Apartment, !- Zone Name T SE Apartment Equipment,!- Zone Conditioning Equipment List Name T SE Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T SE Apartment Air Node, !- Zone Air Node Name T SE Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name ZoneHVAC:EquipmentConnections, T SW Apartment, !- Zone Name T SW Apartment Equipment,!- Zone Conditioning Equipment List Name T SW Apartment Inlet Nodes, !- Zone Air Inlet Node or NodeList Name , !- Zone Air Exhaust Node or NodeList Name T SW Apartment Air Node, !- Zone Air Node Name T SW Apartment Return Air Node Name; !- Zone Return Air Node or NodeList Name NodeList, G Corridor Exhaust Nodes,!- Name G Corridor Unit Heater Exhaust Node; !- Node 1 Name NodeList, G Corridor Inlet Nodes, !- Name G Corridor Unit Heater Inlet Node Name; !- Node 1 Name NodeList, G N1 Apartment Inlet Nodes, !- Name G N1 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, G N2 Apartment Inlet Nodes, !- Name G N2 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, G NE Apartment Inlet Nodes, !- Name G NE Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, G NW Apartment Inlet Nodes, !- Name G NW Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, G S1 Apartment Inlet Nodes, !- Name G S1 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, G S2 Apartment Inlet Nodes, !- Name G S2 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, G SW Apartment Inlet Nodes, !- Name G SW Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M Corridor Exhaust Nodes,!- Name M Corridor Unit Heater Exhaust Node; !- Node 1 Name NodeList, M Corridor Inlet Nodes, !- Name M Corridor Unit Heater Inlet Node Name; !- Node 1 Name NodeList, M N1 Apartment Inlet Nodes, !- Name M N1 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M N2 Apartment Inlet Nodes, !- Name M N2 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M NE Apartment Inlet Nodes, !- Name M NE Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M NW Apartment Inlet Nodes, !- Name M NW Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M S1 Apartment Inlet Nodes, !- Name M S1 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M S2 Apartment Inlet Nodes, !- Name M S2 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M SE Apartment Inlet Nodes, !- Name M SE Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, M SW Apartment Inlet Nodes, !- Name M SW Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, Office Inlet Nodes, !- Name Office Direct Air Inlet Node Name; !- Node 1 Name NodeList, SPLITSYSTEMAC:01_OANode List, !- Name SPLITSYSTEMAC:01_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:02_OANode List, !- Name SPLITSYSTEMAC:02_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:03_OANode List, !- Name SPLITSYSTEMAC:03_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:04_OANode List, !- Name SPLITSYSTEMAC:04_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:05_OANode List, !- Name SPLITSYSTEMAC:05_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:06_OANode List, !- Name SPLITSYSTEMAC:06_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:07_OANode List, !- Name SPLITSYSTEMAC:07_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:08_OANode List, !- Name SPLITSYSTEMAC:08_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:09_OANode List, !- Name SPLITSYSTEMAC:09_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:10_OANode List, !- Name SPLITSYSTEMAC:10_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:11_OANode List, !- Name SPLITSYSTEMAC:11_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:12_OANode List, !- Name SPLITSYSTEMAC:12_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:13_OANode List, !- Name SPLITSYSTEMAC:13_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:14_OANode List, !- Name SPLITSYSTEMAC:14_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:15_OANode List, !- Name SPLITSYSTEMAC:15_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:16_OANode List, !- Name SPLITSYSTEMAC:16_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:17_OANode List, !- Name SPLITSYSTEMAC:17_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:18_OANode List, !- Name SPLITSYSTEMAC:18_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:19_OANode List, !- Name SPLITSYSTEMAC:19_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:20_OANode List, !- Name SPLITSYSTEMAC:20_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:21_OANode List, !- Name SPLITSYSTEMAC:21_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:22_OANode List, !- Name SPLITSYSTEMAC:22_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:23_OANode List, !- Name SPLITSYSTEMAC:23_OAInlet Node; !- Node 1 Name NodeList, SPLITSYSTEMAC:24_OANode List, !- Name SPLITSYSTEMAC:24_OAInlet Node; !- Node 1 Name NodeList, T Corridor Exhaust Nodes,!- Name T Corridor Unit Heater Exhaust Node; !- Node 1 Name NodeList, T Corridor Inlet Nodes, !- Name T Corridor Unit Heater Inlet Node Name; !- Node 1 Name NodeList, T N1 Apartment Inlet Nodes, !- Name T N1 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, T N2 Apartment Inlet Nodes, !- Name T N2 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, T NE Apartment Inlet Nodes, !- Name T NE Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, T NW Apartment Inlet Nodes, !- Name T NW Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, T S1 Apartment Inlet Nodes, !- Name T S1 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, T S2 Apartment Inlet Nodes, !- Name T S2 Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, T SE Apartment Inlet Nodes, !- Name T SE Apartment Direct Air Inlet Node Name; !- Node 1 Name NodeList, T SW Apartment Inlet Nodes, !- Name T SW Apartment Direct Air Inlet Node Name; !- Node 1 Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, G N1 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name G N1 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name G N1 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, G N1 Apartment Direct Air ADU, !- Name G N1 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type G N1 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, G N2 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name G N2 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name G N2 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, G N2 Apartment Direct Air ADU, !- Name G N2 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type G N2 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, G NE Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name G NE Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name G NE Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, G NE Apartment Direct Air ADU, !- Name G NE Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type G NE Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, G NW Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name G NW Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name G NW Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, G NW Apartment Direct Air ADU, !- Name G NW Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type G NW Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, G S1 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name G S1 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name G S1 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, G S1 Apartment Direct Air ADU, !- Name G S1 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type G S1 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, G S2 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name G S2 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name G S2 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, G S2 Apartment Direct Air ADU, !- Name G S2 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type G S2 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, G SW Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name G SW Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name G SW Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, G SW Apartment Direct Air ADU, !- Name G SW Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type G SW Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M N1 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M N1 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M N1 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M N1 Apartment Direct Air ADU, !- Name M N1 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M N1 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M N2 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M N2 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M N2 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M N2 Apartment Direct Air ADU, !- Name M N2 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M N2 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M NE Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M NE Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M NE Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M NE Apartment Direct Air ADU, !- Name M NE Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M NE Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M NW Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M NW Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M NW Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M NW Apartment Direct Air ADU, !- Name M NW Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M NW Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M S1 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M S1 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M S1 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M S1 Apartment Direct Air ADU, !- Name M S1 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M S1 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M S2 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M S2 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M S2 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M S2 Apartment Direct Air ADU, !- Name M S2 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M S2 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M SE Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M SE Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M SE Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M SE Apartment Direct Air ADU, !- Name M SE Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M SE Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, M SW Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name M SW Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name M SW Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, M SW Apartment Direct Air ADU, !- Name M SW Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type M SW Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, Office Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name Office Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name Office Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, Office Direct Air ADU, !- Name Office Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type Office Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T N1 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T N1 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T N1 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T N1 Apartment Direct Air ADU, !- Name T N1 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T N1 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T N2 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T N2 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T N2 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T N2 Apartment Direct Air ADU, !- Name T N2 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T N2 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T NE Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T NE Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T NE Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T NE Apartment Direct Air ADU, !- Name T NE Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T NE Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T NW Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T NW Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T NW Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T NW Apartment Direct Air ADU, !- Name T NW Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T NW Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T S1 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T S1 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T S1 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T S1 Apartment Direct Air ADU, !- Name T S1 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T S1 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T S2 Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T S2 Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T S2 Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T S2 Apartment Direct Air ADU, !- Name T S2 Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T S2 Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T SE Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T SE Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T SE Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T SE Apartment Direct Air ADU, !- Name T SE Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T SE Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, T SW Apartment Direct Air, !- Name ALWAYS_ON, !- Availability Schedule Name T SW Apartment Direct Air Inlet Node Name ATInlet, !- Air Inlet Node Name T SW Apartment Direct Air Inlet Node Name, !- Air Outlet Node Name AUTOSIZE, !- Maximum Air Flow Rate {m3/s} , !- Design Specification Outdoor Air Object Name ; !- Per Person Ventilation Rate Mode ZoneHVAC:AirDistributionUnit, T SW Apartment Direct Air ADU, !- Name T SW Apartment Direct Air Inlet Node Name, !- Air Distribution Unit Outlet Node Name AirTerminal:SingleDuct:ConstantVolume:NoReheat, !- Air Terminal Object Type T SW Apartment Direct Air, !- Air Terminal Name , !- Nominal Upstream Leakage Fraction , !- Constant Downstream Leakage Fraction ; !- Design Specification Air Terminal Sizing Object Name BranchList, SPLITSYSTEMAC:01 Air Loop Branches, !- Name SPLITSYSTEMAC:01 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:02 Air Loop Branches, !- Name SPLITSYSTEMAC:02 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:03 Air Loop Branches, !- Name SPLITSYSTEMAC:03 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:04 Air Loop Branches, !- Name SPLITSYSTEMAC:04 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:05 Air Loop Branches, !- Name SPLITSYSTEMAC:05 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:06 Air Loop Branches, !- Name SPLITSYSTEMAC:06 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:07 Air Loop Branches, !- Name SPLITSYSTEMAC:07 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:08 Air Loop Branches, !- Name SPLITSYSTEMAC:08 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:09 Air Loop Branches, !- Name SPLITSYSTEMAC:09 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:10 Air Loop Branches, !- Name SPLITSYSTEMAC:10 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:11 Air Loop Branches, !- Name SPLITSYSTEMAC:11 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:12 Air Loop Branches, !- Name SPLITSYSTEMAC:12 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:13 Air Loop Branches, !- Name SPLITSYSTEMAC:13 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:14 Air Loop Branches, !- Name SPLITSYSTEMAC:14 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:15 Air Loop Branches, !- Name SPLITSYSTEMAC:15 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:16 Air Loop Branches, !- Name SPLITSYSTEMAC:16 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:17 Air Loop Branches, !- Name SPLITSYSTEMAC:17 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:18 Air Loop Branches, !- Name SPLITSYSTEMAC:18 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:19 Air Loop Branches, !- Name SPLITSYSTEMAC:19 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:20 Air Loop Branches, !- Name SPLITSYSTEMAC:20 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:21 Air Loop Branches, !- Name SPLITSYSTEMAC:21 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:22 Air Loop Branches, !- Name SPLITSYSTEMAC:22 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:23 Air Loop Branches, !- Name SPLITSYSTEMAC:23 Air Loop Main Branch; !- Branch 1 Name BranchList, SPLITSYSTEMAC:24 Air Loop Branches, !- Name SPLITSYSTEMAC:24 Air Loop Main Branch; !- Branch 1 Name Branch, SPLITSYSTEMAC:01 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:01_OA, !- Component 1 Name SPLITSYSTEMAC:01 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:01_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:01_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:01_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:01 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:02 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:02_OA, !- Component 1 Name SPLITSYSTEMAC:02 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:02_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:02_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:02_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:02 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:03 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:03_OA, !- Component 1 Name SPLITSYSTEMAC:03 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:03_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:03_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:03_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:03 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:04 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:04_OA, !- Component 1 Name SPLITSYSTEMAC:04 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:04_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:04_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:04_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:04 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:05 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:05_OA, !- Component 1 Name SPLITSYSTEMAC:05 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:05_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:05_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:05_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:05 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:06 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:06_OA, !- Component 1 Name SPLITSYSTEMAC:06 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:06_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:06_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:06_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:06 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:07 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:07_OA, !- Component 1 Name SPLITSYSTEMAC:07 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:07_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:07_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:07_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:07 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:08 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:08_OA, !- Component 1 Name SPLITSYSTEMAC:08 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:08_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:08_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:08_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:08 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:09 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:09_OA, !- Component 1 Name SPLITSYSTEMAC:09 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:09_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:09_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:09_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:09 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:10 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:10_OA, !- Component 1 Name SPLITSYSTEMAC:10 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:10_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:10_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:10_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:10 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:11 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:11_OA, !- Component 1 Name SPLITSYSTEMAC:11 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:11_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:11_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:11_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:11 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:12 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:12_OA, !- Component 1 Name SPLITSYSTEMAC:12 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:12_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:12_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:12_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:12 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:13 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:13_OA, !- Component 1 Name SPLITSYSTEMAC:13 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:13_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:13_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:13_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:13 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:14 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:14_OA, !- Component 1 Name SPLITSYSTEMAC:14 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:14_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:14_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:14_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:14 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:15 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:15_OA, !- Component 1 Name SPLITSYSTEMAC:15 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:15_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:15_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:15_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:15 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:16 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:16_OA, !- Component 1 Name SPLITSYSTEMAC:16 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:16_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:16_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:16_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:16 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:17 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:17_OA, !- Component 1 Name SPLITSYSTEMAC:17 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:17_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:17_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:17_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:17 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:18 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:18_OA, !- Component 1 Name SPLITSYSTEMAC:18 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:18_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:18_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:18_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:18 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:19 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:19_OA, !- Component 1 Name SPLITSYSTEMAC:19 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:19_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:19_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:19_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:19 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:20 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:20_OA, !- Component 1 Name SPLITSYSTEMAC:20 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:20_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:20_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:20_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:20 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:21 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:21_OA, !- Component 1 Name SPLITSYSTEMAC:21 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:21_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:21_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:21_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:21 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:22 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:22_OA, !- Component 1 Name SPLITSYSTEMAC:22 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:22_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:22_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:22_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:22 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:23 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:23_OA, !- Component 1 Name SPLITSYSTEMAC:23 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:23_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:23_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:23_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:23 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name Branch, SPLITSYSTEMAC:24 Air Loop Main Branch, !- Name , !- Pressure Drop Curve Name AirLoopHVAC:OutdoorAirSystem, !- Component 1 Object Type SPLITSYSTEMAC:24_OA, !- Component 1 Name SPLITSYSTEMAC:24 Supply Equipment Inlet Node, !- Component 1 Inlet Node Name OA-SPLITSYSTEMAC:24_Unitary_PackageNode, !- Component 1 Outlet Node Name AirLoopHVAC:UnitaryHeatCool, !- Component 2 Object Type SPLITSYSTEMAC:24_Unitary_Package, !- Component 2 Name OA-SPLITSYSTEMAC:24_Unitary_PackageNode, !- Component 2 Inlet Node Name SPLITSYSTEMAC:24 Supply Equipment Outlet Node; !- Component 2 Outlet Node Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:01_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:01_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:02_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:02_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:03_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:03_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:04_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:04_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:05_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:05_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:06_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:06_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:07_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:07_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:08_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:08_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:09_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:09_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:10_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:10_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:11_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:11_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:12_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:12_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:13_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:13_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:14_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:14_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:15_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:15_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:16_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:16_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:17_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:17_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:18_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:18_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:19_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:19_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:20_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:20_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:21_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:21_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:22_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:22_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:23_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:23_OA_Controller; !- Controller 1 Name AirLoopHVAC:ControllerList, SPLITSYSTEMAC:24_OA_Controllers, !- Name Controller:OutdoorAir, !- Controller 1 Object Type SPLITSYSTEMAC:24_OA_Controller; !- Controller 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:01_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:01_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:02_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:02_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:03_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:03_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:04_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:04_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:05_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:05_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:06_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:06_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:07_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:07_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:08_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:08_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:09_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:09_OAMixinM Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:10_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:10_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:11_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:11_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:12_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:12_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:13_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:13_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:14_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:14_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:15_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:15_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:16_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:16_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:17_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:17_OAMixinM Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:18_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:18_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:19_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:19_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:20_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:20_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:21_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:21_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:22_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:22_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:23_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:23_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem:EquipmentList, SPLITSYSTEMAC:24_OA_Equipment, !- Name OutdoorAir:Mixer, !- Component 1 Object Type SPLITSYSTEMAC:24_OAMixing Box; !- Component 1 Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:01_OA, !- Name SPLITSYSTEMAC:01_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:01_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:02_OA, !- Name SPLITSYSTEMAC:02_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:02_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:03_OA, !- Name SPLITSYSTEMAC:03_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:03_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:04_OA, !- Name SPLITSYSTEMAC:04_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:04_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:05_OA, !- Name SPLITSYSTEMAC:05_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:05_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:06_OA, !- Name SPLITSYSTEMAC:06_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:06_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:07_OA, !- Name SPLITSYSTEMAC:07_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:07_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:08_OA, !- Name SPLITSYSTEMAC:08_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:08_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:09_OA, !- Name SPLITSYSTEMAC:09_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:09_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:10_OA, !- Name SPLITSYSTEMAC:10_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:10_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:11_OA, !- Name SPLITSYSTEMAC:11_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:11_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:12_OA, !- Name SPLITSYSTEMAC:12_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:12_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:13_OA, !- Name SPLITSYSTEMAC:13_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:13_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:14_OA, !- Name SPLITSYSTEMAC:14_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:14_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:15_OA, !- Name SPLITSYSTEMAC:15_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:15_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:16_OA, !- Name SPLITSYSTEMAC:16_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:16_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:17_OA, !- Name SPLITSYSTEMAC:17_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:17_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:18_OA, !- Name SPLITSYSTEMAC:18_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:18_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:19_OA, !- Name SPLITSYSTEMAC:19_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:19_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:20_OA, !- Name SPLITSYSTEMAC:20_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:20_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:21_OA, !- Name SPLITSYSTEMAC:21_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:21_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:22_OA, !- Name SPLITSYSTEMAC:22_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:22_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:23_OA, !- Name SPLITSYSTEMAC:23_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:23_OA_Equipment; !- Outdoor Air Equipment List Name AirLoopHVAC:OutdoorAirSystem, SPLITSYSTEMAC:24_OA, !- Name SPLITSYSTEMAC:24_OA_Controllers, !- Controller List Name SPLITSYSTEMAC:24_OA_Equipment; !- Outdoor Air Equipment List Name OutdoorAir:NodeList, SPLITSYSTEMAC:01_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:02_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:03_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:04_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:05_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:06_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:07_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:08_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:09_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:10_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:11_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:12_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:13_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:14_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:15_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:16_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:17_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:18_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:19_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:20_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:21_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:22_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:23_OANode List; !- Node or NodeList Name 1 OutdoorAir:NodeList, SPLITSYSTEMAC:24_OANode List; !- Node or NodeList Name 1 OutdoorAir:Mixer, SPLITSYSTEMAC:01_OAMixing Box, !- Name OA-SPLITSYSTEMAC:01_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:01_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:01_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:01 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:02_OAMixing Box, !- Name OA-SPLITSYSTEMAC:02_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:02_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:02_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:02 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:03_OAMixing Box, !- Name OA-SPLITSYSTEMAC:03_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:03_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:03_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:03 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:04_OAMixing Box, !- Name OA-SPLITSYSTEMAC:04_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:04_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:04_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:04 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:05_OAMixing Box, !- Name OA-SPLITSYSTEMAC:05_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:05_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:05_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:05 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:06_OAMixing Box, !- Name OA-SPLITSYSTEMAC:06_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:06_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:06_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:06 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:07_OAMixing Box, !- Name OA-SPLITSYSTEMAC:07_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:07_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:07_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:07 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:08_OAMixing Box, !- Name OA-SPLITSYSTEMAC:08_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:08_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:08_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:08 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:09_OAMixinM Box, !- Name OA-SPLITSYSTEMAC:09_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:09_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:09_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:09 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:10_OAMixing Box, !- Name OA-SPLITSYSTEMAC:10_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:10_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:10_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:10 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:11_OAMixing Box, !- Name OA-SPLITSYSTEMAC:11_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:11_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:11_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:11 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:12_OAMixing Box, !- Name OA-SPLITSYSTEMAC:12_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:12_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:12_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:12 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:13_OAMixing Box, !- Name OA-SPLITSYSTEMAC:13_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:13_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:13_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:13 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:14_OAMixing Box, !- Name OA-SPLITSYSTEMAC:14_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:14_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:14_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:14 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:15_OAMixing Box, !- Name OA-SPLITSYSTEMAC:15_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:15_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:15_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:15 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:16_OAMixing Box, !- Name OA-SPLITSYSTEMAC:16_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:16_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:16_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:16 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:17_OAMixinM Box, !- Name OA-SPLITSYSTEMAC:17_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:17_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:17_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:17 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:18_OAMixing Box, !- Name OA-SPLITSYSTEMAC:18_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:18_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:18_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:18 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:19_OAMixing Box, !- Name OA-SPLITSYSTEMAC:19_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:19_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:19_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:19 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:20_OAMixing Box, !- Name OA-SPLITSYSTEMAC:20_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:20_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:20_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:20 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:21_OAMixing Box, !- Name OA-SPLITSYSTEMAC:21_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:21_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:21_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:21 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:22_OAMixing Box, !- Name OA-SPLITSYSTEMAC:22_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:22_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:22_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:22 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:23_OAMixing Box, !- Name OA-SPLITSYSTEMAC:23_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:23_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:23_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:23 Supply Equipment Inlet Node; !- Return Air Stream Node Name OutdoorAir:Mixer, SPLITSYSTEMAC:24_OAMixing Box, !- Name OA-SPLITSYSTEMAC:24_Unitary_PackageNode, !- Mixed Air Node Name SPLITSYSTEMAC:24_OAInlet Node, !- Outdoor Air Stream Node Name SPLITSYSTEMAC:24_OARelief Node, !- Relief Air Stream Node Name SPLITSYSTEMAC:24 Supply Equipment Inlet Node; !- Return Air Stream Node Name SetpointManager:MixedAir, SPLITSYSTEMAC:01_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:01 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:01_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:01_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:01_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:02_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:02 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:02_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:02_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:02_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:03_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:03 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:03_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:03_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:03_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:04_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:04 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:04_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:04_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:04_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:05_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:05 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:05_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:05_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:05_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:06_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:06 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:06_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:06_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:06_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:07_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:07 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:07_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:07_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:07_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:08_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:08 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:08_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:08_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:08_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:09_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:09 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:09_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:09_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:09_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:10_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:10 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:10_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:10_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:10_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:11_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:11 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:11_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:11_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:11_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:12_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:12 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:12_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:12_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:12_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:13_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:13 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:13_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:13_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:13_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:14_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:14 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:14_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:14_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:14_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:15_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:15 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:15_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:15_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:15_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:16_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:16 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:16_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:16_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:16_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:17_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:17 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:17_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:17_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:17_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:18_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:18 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:18_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:18_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:18_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:19_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:19 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:19_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:19_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:19_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:20_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:20 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:20_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:20_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:20_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:21_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:21 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:21_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:21_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:21_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:22_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:22 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:22_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:22_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:22_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:23_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:23 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:23_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:23_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:23_Unitary_PackageNode; !- Setpoint Node or NodeList Name SetpointManager:MixedAir, SPLITSYSTEMAC:24_OAMixed Air Temp Manager, !- Name Temperature, !- Control Variable SPLITSYSTEMAC:24 Supply Equipment Outlet Node, !- Reference Setpoint Node Name OA-SPLITSYSTEMAC:24_Unitary_PackageNode, !- Fan Inlet Node Name SPLITSYSTEMAC:24_Unitary_PackageCoolCoil air inlet, !- Fan Outlet Node Name OA-SPLITSYSTEMAC:24_Unitary_PackageNode; !- Setpoint Node or NodeList Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:01, !- Name SPLITSYSTEMAC:01 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:01 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:10, !- Name SPLITSYSTEMAC:10 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:10 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:11, !- Name SPLITSYSTEMAC:11 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:11 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:12, !- Name SPLITSYSTEMAC:12 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:12 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:13, !- Name SPLITSYSTEMAC:13 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:13 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:14, !- Name SPLITSYSTEMAC:14 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:14 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:15, !- Name SPLITSYSTEMAC:15 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:15 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:16, !- Name SPLITSYSTEMAC:16 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:16 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:17, !- Name SPLITSYSTEMAC:17 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:17 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:18, !- Name SPLITSYSTEMAC:18 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:18 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:19, !- Name SPLITSYSTEMAC:19 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:19 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:02, !- Name SPLITSYSTEMAC:02 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:02 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:20, !- Name SPLITSYSTEMAC:20 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:20 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:21, !- Name SPLITSYSTEMAC:21 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:21 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:22, !- Name SPLITSYSTEMAC:22 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:22 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:23, !- Name SPLITSYSTEMAC:23 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:23 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:24, !- Name SPLITSYSTEMAC:24 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:24 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:03, !- Name SPLITSYSTEMAC:03 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:03 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:04, !- Name SPLITSYSTEMAC:04 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:04 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:05, !- Name SPLITSYSTEMAC:05 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:05 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:06, !- Name SPLITSYSTEMAC:06 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:06 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:07, !- Name SPLITSYSTEMAC:07 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:07 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:08, !- Name SPLITSYSTEMAC:08 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:08 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:SupplyPath, SPLITSYSTEMAC:09, !- Name SPLITSYSTEMAC:09 Zone Equipment Inlet Node, !- Supply Air Path Inlet Node Name AirLoopHVAC:ZoneSplitter,!- Component 1 Object Type SPLITSYSTEMAC:09 Supply Air Splitter; !- Component 1 Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:01 Supply Air Splitter, !- Name SPLITSYSTEMAC:01 Zone Equipment Inlet Node, !- Inlet Node Name G SW Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:02 Supply Air Splitter, !- Name SPLITSYSTEMAC:02 Zone Equipment Inlet Node, !- Inlet Node Name G NW Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:03 Supply Air Splitter, !- Name SPLITSYSTEMAC:03 Zone Equipment Inlet Node, !- Inlet Node Name Office Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:04 Supply Air Splitter, !- Name SPLITSYSTEMAC:04 Zone Equipment Inlet Node, !- Inlet Node Name G NE Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:05 Supply Air Splitter, !- Name SPLITSYSTEMAC:05 Zone Equipment Inlet Node, !- Inlet Node Name G N1 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:06 Supply Air Splitter, !- Name SPLITSYSTEMAC:06 Zone Equipment Inlet Node, !- Inlet Node Name G N2 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:07 Supply Air Splitter, !- Name SPLITSYSTEMAC:07 Zone Equipment Inlet Node, !- Inlet Node Name G S1 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:08 Supply Air Splitter, !- Name SPLITSYSTEMAC:08 Zone Equipment Inlet Node, !- Inlet Node Name G S2 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:09 Supply Air Splitter, !- Name SPLITSYSTEMAC:09 Zone Equipment Inlet Node, !- Inlet Node Name M SW Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:10 Supply Air Splitter, !- Name SPLITSYSTEMAC:10 Zone Equipment Inlet Node, !- Inlet Node Name M NW Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:11 Supply Air Splitter, !- Name SPLITSYSTEMAC:11 Zone Equipment Inlet Node, !- Inlet Node Name M SE Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:12 Supply Air Splitter, !- Name SPLITSYSTEMAC:12 Zone Equipment Inlet Node, !- Inlet Node Name M NE Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:13 Supply Air Splitter, !- Name SPLITSYSTEMAC:13 Zone Equipment Inlet Node, !- Inlet Node Name M N1 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:14 Supply Air Splitter, !- Name SPLITSYSTEMAC:14 Zone Equipment Inlet Node, !- Inlet Node Name M N2 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:15 Supply Air Splitter, !- Name SPLITSYSTEMAC:15 Zone Equipment Inlet Node, !- Inlet Node Name M S1 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:16 Supply Air Splitter, !- Name SPLITSYSTEMAC:16 Zone Equipment Inlet Node, !- Inlet Node Name M S2 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:17 Supply Air Splitter, !- Name SPLITSYSTEMAC:17 Zone Equipment Inlet Node, !- Inlet Node Name T SW Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:18 Supply Air Splitter, !- Name SPLITSYSTEMAC:18 Zone Equipment Inlet Node, !- Inlet Node Name T NW Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:19 Supply Air Splitter, !- Name SPLITSYSTEMAC:19 Zone Equipment Inlet Node, !- Inlet Node Name T SE Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:20 Supply Air Splitter, !- Name SPLITSYSTEMAC:20 Zone Equipment Inlet Node, !- Inlet Node Name T NE Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:21 Supply Air Splitter, !- Name SPLITSYSTEMAC:21 Zone Equipment Inlet Node, !- Inlet Node Name T N1 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:22 Supply Air Splitter, !- Name SPLITSYSTEMAC:22 Zone Equipment Inlet Node, !- Inlet Node Name T N2 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:23 Supply Air Splitter, !- Name SPLITSYSTEMAC:23 Zone Equipment Inlet Node, !- Inlet Node Name T S1 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ZoneSplitter, SPLITSYSTEMAC:24 Supply Air Splitter, !- Name SPLITSYSTEMAC:24 Zone Equipment Inlet Node, !- Inlet Node Name T S2 Apartment Direct Air Inlet Node Name ATInlet; !- Outlet 1 Node Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:01 Return Air Path, !- Name SPLITSYSTEMAC:01 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:01 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:02 Return Air Path, !- Name SPLITSYSTEMAC:02 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:02 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:03 Return Air Path, !- Name SPLITSYSTEMAC:03 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:03 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:04 Return Air Path, !- Name SPLITSYSTEMAC:04 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:04 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:05 Return Air Path, !- Name SPLITSYSTEMAC:05 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:05 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:06 Return Air Path, !- Name SPLITSYSTEMAC:06 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:06 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:07 Return Air Path, !- Name SPLITSYSTEMAC:07 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:07 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:08 Return Air Path, !- Name SPLITSYSTEMAC:08 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:08 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:09 Return Air Path, !- Name SPLITSYSTEMAC:09 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:09 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:10 Return Air Path, !- Name SPLITSYSTEMAC:10 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:10 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:11 Return Air Path, !- Name SPLITSYSTEMAC:11 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:11 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:12 Return Air Path, !- Name SPLITSYSTEMAC:12 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:12 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:13 Return Air Path, !- Name SPLITSYSTEMAC:13 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:13 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:14 Return Air Path, !- Name SPLITSYSTEMAC:14 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:14 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:15 Return Air Path, !- Name SPLITSYSTEMAC:15 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:15 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:16 Return Air Path, !- Name SPLITSYSTEMAC:16 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:16 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:17 Return Air Path, !- Name SPLITSYSTEMAC:17 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:17 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:18 Return Air Path, !- Name SPLITSYSTEMAC:18 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:18 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:19 Return Air Path, !- Name SPLITSYSTEMAC:19 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:19 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:20 Return Air Path, !- Name SPLITSYSTEMAC:20 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:20 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:21 Return Air Path, !- Name SPLITSYSTEMAC:21 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:21 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:22 Return Air Path, !- Name SPLITSYSTEMAC:22 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:22 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:23 Return Air Path, !- Name SPLITSYSTEMAC:23 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:23 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ReturnPath, SPLITSYSTEMAC:24 Return Air Path, !- Name SPLITSYSTEMAC:24 Zone Equipment Outlet Node, !- Return Air Path Outlet Node Name AirLoopHVAC:ZoneMixer, !- Component 1 Object Type SPLITSYSTEMAC:24 Return Air Mixer; !- Component 1 Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:01 Return Air Mixer, !- Name SPLITSYSTEMAC:01 Zone Equipment Outlet Node, !- Outlet Node Name G SW Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:02 Return Air Mixer, !- Name SPLITSYSTEMAC:02 Zone Equipment Outlet Node, !- Outlet Node Name G NW Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:03 Return Air Mixer, !- Name SPLITSYSTEMAC:03 Zone Equipment Outlet Node, !- Outlet Node Name Office Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:04 Return Air Mixer, !- Name SPLITSYSTEMAC:04 Zone Equipment Outlet Node, !- Outlet Node Name G NE Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:05 Return Air Mixer, !- Name SPLITSYSTEMAC:05 Zone Equipment Outlet Node, !- Outlet Node Name G N1 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:06 Return Air Mixer, !- Name SPLITSYSTEMAC:06 Zone Equipment Outlet Node, !- Outlet Node Name G N2 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:07 Return Air Mixer, !- Name SPLITSYSTEMAC:07 Zone Equipment Outlet Node, !- Outlet Node Name G S1 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:08 Return Air Mixer, !- Name SPLITSYSTEMAC:08 Zone Equipment Outlet Node, !- Outlet Node Name G S2 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:09 Return Air Mixer, !- Name SPLITSYSTEMAC:09 Zone Equipment Outlet Node, !- Outlet Node Name M SW Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:10 Return Air Mixer, !- Name SPLITSYSTEMAC:10 Zone Equipment Outlet Node, !- Outlet Node Name M NW Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:11 Return Air Mixer, !- Name SPLITSYSTEMAC:11 Zone Equipment Outlet Node, !- Outlet Node Name M SE Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:12 Return Air Mixer, !- Name SPLITSYSTEMAC:12 Zone Equipment Outlet Node, !- Outlet Node Name M NE Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:13 Return Air Mixer, !- Name SPLITSYSTEMAC:13 Zone Equipment Outlet Node, !- Outlet Node Name M N1 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:14 Return Air Mixer, !- Name SPLITSYSTEMAC:14 Zone Equipment Outlet Node, !- Outlet Node Name M N2 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:15 Return Air Mixer, !- Name SPLITSYSTEMAC:15 Zone Equipment Outlet Node, !- Outlet Node Name M S1 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:16 Return Air Mixer, !- Name SPLITSYSTEMAC:16 Zone Equipment Outlet Node, !- Outlet Node Name M S2 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:17 Return Air Mixer, !- Name SPLITSYSTEMAC:17 Zone Equipment Outlet Node, !- Outlet Node Name T SW Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:18 Return Air Mixer, !- Name SPLITSYSTEMAC:18 Zone Equipment Outlet Node, !- Outlet Node Name T NW Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:19 Return Air Mixer, !- Name SPLITSYSTEMAC:19 Zone Equipment Outlet Node, !- Outlet Node Name T SE Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:20 Return Air Mixer, !- Name SPLITSYSTEMAC:20 Zone Equipment Outlet Node, !- Outlet Node Name T NE Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:21 Return Air Mixer, !- Name SPLITSYSTEMAC:21 Zone Equipment Outlet Node, !- Outlet Node Name T N1 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:22 Return Air Mixer, !- Name SPLITSYSTEMAC:22 Zone Equipment Outlet Node, !- Outlet Node Name T N2 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:23 Return Air Mixer, !- Name SPLITSYSTEMAC:23 Zone Equipment Outlet Node, !- Outlet Node Name T S1 Apartment Return Air Node Name; !- Inlet 1 Node Name AirLoopHVAC:ZoneMixer, SPLITSYSTEMAC:24 Return Air Mixer, !- Name SPLITSYSTEMAC:24 Zone Equipment Outlet Node, !- Outlet Node Name T S2 Apartment Return Air Node Name; !- Inlet 1 Node Name ! ***SCHEDULES*** Schedule:Compact, UnitHeater_ClgSP_Sch, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR:AllDays, !- Field 2 UNTIL: 24:00,40; !- Field 3 Schedule:Compact, UnitHeater_HtgSP_Sch, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR:AllDays, !- Field 2 UNTIL: 24:00,15.6; !- Field 3 Schedule:Compact, APT_CLGSETP_SCH, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR:AllDays, !- Field 2 UNTIL: 24:00,23.9; !- Field 3 Schedule:Compact, APT_HTGSETP_SCH, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR:AllDays, !- Field 2 UNTIL: 24:00,21.1; !- Field 3 Schedule:Compact, OFF_HTGSETP_SCH, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR:Weekdays WinterDesignDay, !- Field 2 UNTIL: 7:00,15.6, !- Field 3 UNTIL: 8:00,18.3, !- Field 5 UNTIL:17:00,21.1, !- Field 7 UNTIL: 18:00,18.3, !- Field 9 UNTIL: 24:00,15.6, !- Field 11 FOR: AllOtherDays, !- Field 13 UNTIL: 24:00,15.6; !- Field 14 Schedule:Compact, OFF_CLGSETP_SCH, !- Name Temperature, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR:Weekdays SummerDesignDay, !- Field 2 UNTIL: 7:00,29.4, !- Field 3 UNTIL: 8:00,26.7, !- Field 5 UNTIL:17:00,23.9, !- Field 7 UNTIL: 18:00,26.7, !- Field 9 UNTIL: 24:00,29.4, !- Field 11 FOR: AllOtherDays, !- Field 13 UNTIL: 24:00,29.4; !- Field 14 Schedule:Compact, Dual Zone Control Type Sched, !- Name Control Type, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,4; !- Field 3 Schedule:Compact, Apt_Operation, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0; !- Field 3 Schedule:Compact, Office_Operation, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: Weekdays SummerDesignDay WinterDesignDay, !- Field 2 Until: 8:00,0.0, !- Field 3 Until: 17:00,1.0, !- Field 5 Until: 24:00,0.0, !- Field 7 For AllOtherDays, !- Field 9 Until: 24:00,0.0; !- Field 10 Schedule:Compact, MinOA_Sched, !- Name On/Off, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,1; !- Field 3 ! Service water heating to 23 apartments, circulating gas-fired boiler loop ! ***SWH EQUIPMENT*** WaterHeater:Mixed, SWHSys1 Water Heater, !- Name 0.003785, !- Tank Volume {m3} SWHSys1 Water Heater Setpoint Temperature Schedule Name, !- Setpoint Temperature Schedule Name , !- Deadband Temperature Difference {deltaC} 82.2222, !- Maximum Temperature Limit {C} Modulate, !- Heater Control Type 211500, !- Heater Maximum Capacity {W} , !- Heater Minimum Capacity {W} , !- Heater Ignition Minimum Flow Rate {m3/s} , !- Heater Ignition Delay {s} NATURALGAS, !- Heater Fuel Type 0.8, !- Heater Thermal Efficiency , !- Part Load Factor Curve Name 2, !- Off Cycle Parasitic Fuel Consumption Rate {W} NATURALGAS, !- Off Cycle Parasitic Fuel Type 0.8, !- Off Cycle Parasitic Heat Fraction to Tank , !- On Cycle Parasitic Fuel Consumption Rate {W} NATURALGAS, !- On Cycle Parasitic Fuel Type , !- On Cycle Parasitic Heat Fraction to Tank Schedule, !- Ambient Temperature Indicator SWHSys1 Water Heater Ambient Temperature Schedule Name, !- Ambient Temperature Schedule Name , !- Ambient Temperature Zone Name , !- Ambient Temperature Outdoor Air Node Name 6.0, !- Off Cycle Loss Coefficient to Ambient Temperature {W/K} , !- Off Cycle Loss Fraction to Zone 6.0, !- On Cycle Loss Coefficient to Ambient Temperature {W/K} , !- On Cycle Loss Fraction to Zone , !- Peak Use Flow Rate {m3/s} , !- Use Flow Rate Fraction Schedule Name , !- Cold Water Supply Temperature Schedule Name SWHSys1 Pump-SWHSys1 Water HeaterNode, !- Use Side Inlet Node Name SWHSys1 Supply Equipment Outlet Node, !- Use Side Outlet Node Name 1.0, !- Use Side Effectiveness , !- Source Side Inlet Node Name , !- Source Side Outlet Node Name , !- Source Side Effectiveness AUTOSIZE, !- Use Side Design Flow Rate {m3/s} AUTOSIZE, !- Source Side Design Flow Rate {m3/s} 1.5; !- Indirect Water Heating Recovery Time {hr} WaterUse:Equipment, G SW Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name G SW Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, G NW Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name G NW Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, G NE Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name G NE Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, G N1 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name G N1 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, G N2 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name G N2 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, G S1 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name G S1 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, G S2 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name G S2 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M SW Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M SW Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M NW Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M NW Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M SE Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M SE Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M NE Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M NE Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M N1 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M N1 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M N2 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M N2 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M S1 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M S1 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, M S2 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name M S2 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T SW Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T SW Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T NW Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T NW Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T SE Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T SE Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T NE Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T NE Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T N1 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T N1 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T N2 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T N2 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T S1 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T S1 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name WaterUse:Equipment, T S2 Apartment Water Equipment, !- Name , !- End-Use Subcategory 3.66e-006, !- Peak Flow Rate {m3/s} APT_DHW_SCH, !- Flow Rate Fraction Schedule Name Apartment Water Equipment Temp Sched, !- Target Temperature Schedule Name Apartment Water Equipment Hot Supply Temp Sched, !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name T S2 Apartment, !- Zone Name Apartment Water Equipment Sensible fract sched, !- Sensible Fraction Schedule Name Apartment Water Equipment Latent fract sched; !- Latent Fraction Schedule Name PlantEquipmentList, SWHSys1 Equipment List, !- Name WaterHeater:Mixed, !- Equipment 1 Object Type SWHSys1 Water Heater; !- Equipment 1 Name Pump:VariableSpeed, SWHSys1 Pump, !- Name SWHSys1 Supply Inlet Node, !- Inlet Node Name SWHSys1 Pump-SWHSys1 Water HeaterNodeviaConnector, !- Outlet Node Name AUTOSIZE, !- Design Maximum Flow Rate {m3/s} 0.01, !- Design Pump Head {Pa} AUTOSIZE, !- Design Power Consumption {W} 1, !- Motor Efficiency 0.0, !- Fraction of Motor Inefficiencies to Fluid Stream 0, !- Coefficient 1 of the Part Load Performance Curve 1, !- Coefficient 2 of the Part Load Performance Curve 0, !- Coefficient 3 of the Part Load Performance Curve 0, !- Coefficient 4 of the Part Load Performance Curve 0.0, !- Design Minimum Flow Rate {m3/s} Intermittent, !- Pump Control Type ; !- Pump Flow Rate Schedule Name ! ***SWH SIZING & CONTROLS*** Sizing:Plant, SWHSys1, !- Plant or Condenser Loop Name Heating, !- Loop Type 55, !- Design Loop Exit Temperature {C} 5.0; !- Loop Design Temperature Difference {deltaC} SetpointManager:Scheduled, SWHSys1 Loop Setpoint Manager, !- Name Temperature, !- Control Variable SWHSys1-Loop-Temp-Schedule, !- Schedule Name SWHSys1 Supply Outlet Node; !- Setpoint Node or NodeList Name PlantEquipmentOperationSchemes, SWHSys1 Loop Operation Scheme List, !- Name PlantEquipmentOperation:HeatingLoad, !- Control Scheme 1 Object Type SWHSys1 Operation Scheme,!- Control Scheme 1 Name ALWAYS_ON; !- Control Scheme 1 Schedule Name PlantEquipmentOperation:HeatingLoad, SWHSys1 Operation Scheme,!- Name 0.0, !- Load Range 1 Lower Limit {W} 1000000000000000, !- Load Range 1 Upper Limit {W} SWHSys1 Equipment List; !- Range 1 Equipment List Name ! ***SWH LOOP*** PlantLoop, SWHSys1, !- Name Water, !- Fluid Type , !- User Defined Fluid Type SWHSys1 Loop Operation Scheme List, !- Plant Equipment Operation Scheme Name SWHSys1 Supply Outlet Node, !- Loop Temperature Setpoint Node Name 60.0, !- Maximum Loop Temperature {C} 10.0, !- Minimum Loop Temperature {C} AUTOSIZE, !- Maximum Loop Flow Rate {m3/s} 0.0, !- Minimum Loop Flow Rate {m3/s} AUTOSIZE, !- Plant Loop Volume {m3} SWHSys1 Supply Inlet Node, !- Plant Side Inlet Node Name SWHSys1 Supply Outlet Node, !- Plant Side Outlet Node Name SWHSys1 Supply Branches, !- Plant Side Branch List Name SWHSys1 Supply Connectors, !- Plant Side Connector List Name SWHSys1 Demand Inlet Node, !- Demand Side Inlet Node Name SWHSys1 Demand Outlet Node, !- Demand Side Outlet Node Name SWHSys1 Demand Branches, !- Demand Side Branch List Name SWHSys1 Demand Connectors, !- Demand Side Connector List Name Optimal; !- Load Distribution Scheme ! ***SWH CONNECTIONS*** BranchList, SWHSys1 Supply Branches, !- Name SWHSys1 Supply Inlet Branch, !- Branch 1 Name SWHSys1 Supply Equipment Branch, !- Branch 2 Name SWHSys1 Supply Equipment Bypass Branch, !- Branch 3 Name SWHSys1 Supply Outlet Branch; !- Branch 4 Name BranchList, SWHSys1 Demand Branches, !- Name SWHSys1 Demand Inlet Branch, !- Branch 1 Name SWHSys1 Demand Load Branch 1, !- Branch 2 Name SWHSys1 Demand Load Branch 2, !- Branch 3 Name SWHSys1 Demand Load Branch 3, !- Branch 4 Name SWHSys1 Demand Load Branch 4, !- Branch 5 Name SWHSys1 Demand Load Branch 5, !- Branch 6 Name SWHSys1 Demand Load Branch 6, !- Branch 7 Name SWHSys1 Demand Load Branch 7, !- Branch 8 Name SWHSys1 Demand Load Branch 8, !- Branch 9 Name SWHSys1 Demand Load Branch 9, !- Branch 10 Name SWHSys1 Demand Load Branch 10, !- Branch 11 Name SWHSys1 Demand Load Branch 11, !- Branch 12 Name SWHSys1 Demand Load Branch 12, !- Branch 13 Name SWHSys1 Demand Load Branch 13, !- Branch 14 Name SWHSys1 Demand Load Branch 14, !- Branch 15 Name SWHSys1 Demand Load Branch 15, !- Branch 16 Name SWHSys1 Demand Load Branch 16, !- Branch 17 Name SWHSys1 Demand Load Branch 17, !- Branch 18 Name SWHSys1 Demand Load Branch 18, !- Branch 19 Name SWHSys1 Demand Load Branch 19, !- Branch 20 Name SWHSys1 Demand Load Branch 20, !- Branch 21 Name SWHSys1 Demand Load Branch 21, !- Branch 22 Name SWHSys1 Demand Load Branch 22, !- Branch 23 Name SWHSys1 Demand Load Branch 23, !- Branch 24 Name SWHSys1 Demand Bypass Branch, !- Branch 25 Name SWHSys1 Demand Outlet Branch; !- Branch 26 Name ConnectorList, SWHSys1 Supply Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type SWHSys1 Supply Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type SWHSys1 Supply Mixer; !- Connector 2 Name ConnectorList, SWHSys1 Demand Connectors, !- Name Connector:Splitter, !- Connector 1 Object Type SWHSys1 Demand Splitter, !- Connector 1 Name Connector:Mixer, !- Connector 2 Object Type SWHSys1 Demand Mixer; !- Connector 2 Name WaterUse:Connections, G SW Apartment Water Equipment, !- Name G SW Apartment Water Equipment Water Inlet Node, !- Inlet Node Name G SW Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} G SW Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, G NW Apartment Water Equipment, !- Name G NW Apartment Water Equipment Water Inlet Node, !- Inlet Node Name G NW Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} G NW Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, G NE Apartment Water Equipment, !- Name G NE Apartment Water Equipment Water Inlet Node, !- Inlet Node Name G NE Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} G NE Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, G N1 Apartment Water Equipment, !- Name G N1 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name G N1 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} G N1 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, G N2 Apartment Water Equipment, !- Name G N2 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name G N2 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} G N2 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, G S1 Apartment Water Equipment, !- Name G S1 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name G S1 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} G S1 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, G S2 Apartment Water Equipment, !- Name G S2 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name G S2 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} G S2 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M SW Apartment Water Equipment, !- Name M SW Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M SW Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M SW Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M NW Apartment Water Equipment, !- Name M NW Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M NW Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M NW Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M SE Apartment Water Equipment, !- Name M SE Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M SE Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M SE Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M NE Apartment Water Equipment, !- Name M NE Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M NE Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M NE Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M N1 Apartment Water Equipment, !- Name M N1 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M N1 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M N1 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M N2 Apartment Water Equipment, !- Name M N2 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M N2 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M N2 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M S1 Apartment Water Equipment, !- Name M S1 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M S1 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M S1 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, M S2 Apartment Water Equipment, !- Name M S2 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name M S2 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} M S2 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T SW Apartment Water Equipment, !- Name T SW Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T SW Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T SW Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T NW Apartment Water Equipment, !- Name T NW Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T NW Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T NW Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T SE Apartment Water Equipment, !- Name T SE Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T SE Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T SE Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T NE Apartment Water Equipment, !- Name T NE Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T NE Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T NE Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T N1 Apartment Water Equipment, !- Name T N1 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T N1 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T N1 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T N2 Apartment Water Equipment, !- Name T N2 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T N2 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T N2 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T S1 Apartment Water Equipment, !- Name T S1 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T S1 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T S1 Apartment Water Equipment; !- Water Use Equipment 1 Name WaterUse:Connections, T S2 Apartment Water Equipment, !- Name T S2 Apartment Water Equipment Water Inlet Node, !- Inlet Node Name T S2 Apartment Water Equipment Water Outlet Node, !- Outlet Node Name , !- Supply Water Storage Tank Name , !- Reclamation Water Storage Tank Name , !- Hot Water Supply Temperature Schedule Name , !- Cold Water Supply Temperature Schedule Name , !- Drain Water Heat Exchanger Type , !- Drain Water Heat Exchanger Destination , !- Drain Water Heat Exchanger U-Factor Times Area {W/K} T S2 Apartment Water Equipment; !- Water Use Equipment 1 Name Branch, SWHSys1 Supply Inlet Branch, !- Name , !- Pressure Drop Curve Name Pump:VariableSpeed, !- Component 1 Object Type SWHSys1 Pump, !- Component 1 Name SWHSys1 Supply Inlet Node, !- Component 1 Inlet Node Name SWHSys1 Pump-SWHSys1 Water HeaterNodeviaConnector; !- Component 1 Outlet Node Name Branch, SWHSys1 Supply Equipment Branch, !- Name , !- Pressure Drop Curve Name WaterHeater:Mixed, !- Component 1 Object Type SWHSys1 Water Heater, !- Component 1 Name SWHSys1 Pump-SWHSys1 Water HeaterNode, !- Component 1 Inlet Node Name SWHSys1 Supply Equipment Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Supply Equipment Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SWHSys1 Supply Equipment Bypass Pipe, !- Component 1 Name SWHSys1 Supply Equip Bypass Inlet Node, !- Component 1 Inlet Node Name SWHSys1 Supply Equip Bypass Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Supply Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SWHSys1 Supply Outlet Pipe, !- Component 1 Name SWHSys1 Supply Mixer-SWHSys1 Supply Outlet Pipe, !- Component 1 Inlet Node Name SWHSys1 Supply Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Inlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SWHSys1 Demand Inlet Pipe, !- Component 1 Name SWHSys1 Demand Inlet Node, !- Component 1 Inlet Node Name SWHSys1 Demand Inlet Pipe-SWHSys1 Demand Mixer; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 1, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type G SW Apartment Water Equipment, !- Component 1 Name G SW Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name G SW Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 2, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type G NW Apartment Water Equipment, !- Component 1 Name G NW Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name G NW Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 3, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type G NE Apartment Water Equipment, !- Component 1 Name G NE Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name G NE Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 4, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type G N1 Apartment Water Equipment, !- Component 1 Name G N1 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name G N1 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 5, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type G N2 Apartment Water Equipment, !- Component 1 Name G N2 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name G N2 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 6, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type G S1 Apartment Water Equipment, !- Component 1 Name G S1 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name G S1 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 7, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type G S2 Apartment Water Equipment, !- Component 1 Name G S2 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name G S2 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 8, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M SW Apartment Water Equipment, !- Component 1 Name M SW Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M SW Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 9, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M NW Apartment Water Equipment, !- Component 1 Name M NW Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M NW Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 10, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M SE Apartment Water Equipment, !- Component 1 Name M SE Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M SE Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 11, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M NE Apartment Water Equipment, !- Component 1 Name M NE Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M NE Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 12, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M N1 Apartment Water Equipment, !- Component 1 Name M N1 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M N1 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 13, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M N2 Apartment Water Equipment, !- Component 1 Name M N2 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M N2 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 14, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M S1 Apartment Water Equipment, !- Component 1 Name M S1 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M S1 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 15, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type M S2 Apartment Water Equipment, !- Component 1 Name M S2 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name M S2 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 16, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T SW Apartment Water Equipment, !- Component 1 Name T SW Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T SW Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 17, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T NW Apartment Water Equipment, !- Component 1 Name T NW Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T NW Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 18, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T SE Apartment Water Equipment, !- Component 1 Name T SE Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T SE Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 19, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T NE Apartment Water Equipment, !- Component 1 Name T NE Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T NE Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 20, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T N1 Apartment Water Equipment, !- Component 1 Name T N1 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T N1 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 21, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T N2 Apartment Water Equipment, !- Component 1 Name T N2 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T N2 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 22, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T S1 Apartment Water Equipment, !- Component 1 Name T S1 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T S1 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Load Branch 23, !- Name , !- Pressure Drop Curve Name WaterUse:Connections, !- Component 1 Object Type T S2 Apartment Water Equipment, !- Component 1 Name T S2 Apartment Water Equipment Water Inlet Node, !- Component 1 Inlet Node Name T S2 Apartment Water Equipment Water Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Bypass Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SWHSys1 Demand Bypass Pipe, !- Component 1 Name SWHSys1 Demand Bypass Pipe Inlet Node, !- Component 1 Inlet Node Name SWHSys1 Demand Bypass Pipe Outlet Node; !- Component 1 Outlet Node Name Branch, SWHSys1 Demand Outlet Branch, !- Name , !- Pressure Drop Curve Name Pipe:Adiabatic, !- Component 1 Object Type SWHSys1 Demand Outlet Pipe, !- Component 1 Name SWHSys1 Demand Mixer-SWHSys1 Demand Outlet Pipe, !- Component 1 Inlet Node Name SWHSys1 Demand Outlet Node; !- Component 1 Outlet Node Name Connector:Splitter, SWHSys1 Supply Splitter, !- Name SWHSys1 Supply Inlet Branch, !- Inlet Branch Name SWHSys1 Supply Equipment Branch, !- Outlet Branch 1 Name SWHSys1 Supply Equipment Bypass Branch; !- Outlet Branch 2 Name Connector:Splitter, SWHSys1 Demand Splitter, !- Name SWHSys1 Demand Inlet Branch, !- Inlet Branch Name SWHSys1 Demand Load Branch 1, !- Outlet Branch 1 Name SWHSys1 Demand Load Branch 2, !- Outlet Branch 2 Name SWHSys1 Demand Load Branch 3, !- Outlet Branch 3 Name SWHSys1 Demand Load Branch 4, !- Outlet Branch 4 Name SWHSys1 Demand Load Branch 5, !- Outlet Branch 5 Name SWHSys1 Demand Load Branch 6, !- Outlet Branch 6 Name SWHSys1 Demand Load Branch 7, !- Outlet Branch 7 Name SWHSys1 Demand Load Branch 8, !- Outlet Branch 8 Name SWHSys1 Demand Load Branch 9, !- Outlet Branch 9 Name SWHSys1 Demand Load Branch 10, !- Outlet Branch 10 Name SWHSys1 Demand Load Branch 11, !- Outlet Branch 11 Name SWHSys1 Demand Load Branch 12, !- Outlet Branch 12 Name SWHSys1 Demand Load Branch 13, !- Outlet Branch 13 Name SWHSys1 Demand Load Branch 14, !- Outlet Branch 14 Name SWHSys1 Demand Load Branch 15, !- Outlet Branch 15 Name SWHSys1 Demand Load Branch 16, !- Outlet Branch 16 Name SWHSys1 Demand Load Branch 17, !- Outlet Branch 17 Name SWHSys1 Demand Load Branch 18, !- Outlet Branch 18 Name SWHSys1 Demand Load Branch 19, !- Outlet Branch 19 Name SWHSys1 Demand Load Branch 20, !- Outlet Branch 20 Name SWHSys1 Demand Load Branch 21, !- Outlet Branch 21 Name SWHSys1 Demand Load Branch 22, !- Outlet Branch 22 Name SWHSys1 Demand Load Branch 23, !- Outlet Branch 23 Name SWHSys1 Demand Bypass Branch; !- Outlet Branch 24 Name Connector:Mixer, SWHSys1 Supply Mixer, !- Name SWHSys1 Supply Outlet Branch, !- Outlet Branch Name SWHSys1 Supply Equipment Branch, !- Inlet Branch 1 Name SWHSys1 Supply Equipment Bypass Branch; !- Inlet Branch 2 Name Connector:Mixer, SWHSys1 Demand Mixer, !- Name SWHSys1 Demand Outlet Branch, !- Outlet Branch Name SWHSys1 Demand Load Branch 1, !- Inlet Branch 1 Name SWHSys1 Demand Load Branch 2, !- Inlet Branch 2 Name SWHSys1 Demand Load Branch 3, !- Inlet Branch 3 Name SWHSys1 Demand Load Branch 4, !- Inlet Branch 4 Name SWHSys1 Demand Load Branch 5, !- Inlet Branch 5 Name SWHSys1 Demand Load Branch 6, !- Inlet Branch 6 Name SWHSys1 Demand Load Branch 7, !- Inlet Branch 7 Name SWHSys1 Demand Load Branch 8, !- Inlet Branch 8 Name SWHSys1 Demand Load Branch 9, !- Inlet Branch 9 Name SWHSys1 Demand Load Branch 10, !- Inlet Branch 10 Name SWHSys1 Demand Load Branch 11, !- Inlet Branch 11 Name SWHSys1 Demand Load Branch 12, !- Inlet Branch 12 Name SWHSys1 Demand Load Branch 13, !- Inlet Branch 13 Name SWHSys1 Demand Load Branch 14, !- Inlet Branch 14 Name SWHSys1 Demand Load Branch 15, !- Inlet Branch 15 Name SWHSys1 Demand Load Branch 16, !- Inlet Branch 16 Name SWHSys1 Demand Load Branch 17, !- Inlet Branch 17 Name SWHSys1 Demand Load Branch 18, !- Inlet Branch 18 Name SWHSys1 Demand Load Branch 19, !- Inlet Branch 19 Name SWHSys1 Demand Load Branch 20, !- Inlet Branch 20 Name SWHSys1 Demand Load Branch 21, !- Inlet Branch 21 Name SWHSys1 Demand Load Branch 22, !- Inlet Branch 22 Name SWHSys1 Demand Load Branch 23, !- Inlet Branch 23 Name SWHSys1 Demand Bypass Branch; !- Inlet Branch 24 Name Pipe:Adiabatic, SWHSys1 Supply Outlet Pipe, !- Name SWHSys1 Supply Mixer-SWHSys1 Supply Outlet Pipe, !- Inlet Node Name SWHSys1 Supply Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SWHSys1 Supply Equipment Bypass Pipe, !- Name SWHSys1 Supply Equip Bypass Inlet Node, !- Inlet Node Name SWHSys1 Supply Equip Bypass Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SWHSys1 Demand Inlet Pipe, !- Name SWHSys1 Demand Inlet Node, !- Inlet Node Name SWHSys1 Demand Inlet Pipe-SWHSys1 Demand Mixer; !- Outlet Node Name Pipe:Adiabatic, SWHSys1 Demand Outlet Pipe, !- Name SWHSys1 Demand Mixer-SWHSys1 Demand Outlet Pipe, !- Inlet Node Name SWHSys1 Demand Outlet Node; !- Outlet Node Name Pipe:Adiabatic, SWHSys1 Demand Bypass Pipe, !- Name SWHSys1 Demand Bypass Pipe Inlet Node, !- Inlet Node Name SWHSys1 Demand Bypass Pipe Outlet Node; !- Outlet Node Name ! ***SWH SCHEDULES*** Schedule:Compact, Apartment Water Equipment Latent fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.05; !- Field 3 Schedule:Compact, Apartment Water Equipment Sensible fract sched, !- Name Fraction, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,0.2; !- Field 3 Schedule:Compact, Apartment Water Equipment Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,43.3; !- Field 3 Schedule:Compact, Apartment Water Equipment Hot Supply Temp Sched, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,43.3; !- Field 3 Schedule:Compact, SWHSys1 Water Heater Setpoint Temperature Schedule Name, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.0; !- Field 3 Schedule:Compact, SWHSys1 Water Heater Ambient Temperature Schedule Name, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,22.0; !- Field 3 Schedule:Compact, SWHSys1-Loop-Temp-Schedule, !- Name Temperature, !- Schedule Type Limits Name Through: 12/31, !- Field 1 For: AllDays, !- Field 2 Until: 24:00,60.0; !- Field 3 Schedule:Compact, APT_DHW_SCH, !- Name Fraction, !- Schedule Type Limits Name THROUGH: 12/31, !- Field 1 FOR: AllDays, !- Field 2 UNTIL: 1:00,0.08, !- Field 3 UNTIL: 2:00,0.04, !- Field 5 UNTIL: 3:00,0.01, !- Field 7 UNTIL: 4:00,0.01, !- Field 9 UNTIL: 5:00,0.04, !- Field 11 UNTIL: 6:00,0.27, !- Field 13 UNTIL: 7:00,0.94, !- Field 15 UNTIL: 8:00,1.00, !- Field 17 UNTIL: 9:00,0.96, !- Field 19 UNTIL: 10:00,0.84, !- Field 21 UNTIL: 11:00,0.76, !- Field 23 UNTIL: 12:00,0.61, !- Field 25 UNTIL: 13:00,0.53, !- Field 27 UNTIL: 14:00,0.47, !- Field 29 UNTIL: 15:00,0.41, !- Field 31 UNTIL: 16:00,0.47, !- Field 33 UNTIL: 17:00,0.55, !- Field 35 UNTIL: 18:00,0.73, !- Field 37 UNTIL: 19:00,0.86, !- Field 39 UNTIL: 20:00,0.82, !- Field 41 UNTIL: 21:00,0.75, !- Field 43 UNTIL: 22:00,0.61, !- Field 45 UNTIL: 23:00,0.53, !- Field 47 UNTIL: 24:00,0.29; !- Field 49 ! ***ECONOMICS*** ! IN_EIAMonthlyRateGas, Source EIA historical Nov2003 thru Oct2004 ! Indiana 1999 state average electricity emissions factors based on eGRID, 1065, AirData ! PSI_CS_CommercialElectricService, source http://www.cinergypsi.com/pdfs/RateCS.pdf, effective 2004-05-24 ! PSI_LLF_LowLoadFactorService,source http://www.cinergypsi.com/pdfs/RATELLF.pdf, effective 2004-05-24 UtilityCost:Tariff, PSI_LLF_LowLoadFactorService, !- Name Electricity:Facility, !- Output Meter Name kWh, !- Conversion Factor Choice , !- Energy Conversion Factor , !- Demand Conversion Factor , !- Time of Use Period Schedule Name , !- Season Schedule Name , !- Month Schedule Name HalfHour, !- Demand Window Length 15.00, !- Monthly Charge or Variable Name , !- Minimum Monthly Charge or Variable Name , !- Real Time Pricing Charge Schedule Name , !- Customer Baseline Load Schedule Name Comm Elect; !- Group Name UtilityCost:Charge:Block, AnnualEnergyCharge, !- Utility Cost Charge Block Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name , !- Remaining Into Variable , !- Block Size Multiplier Value or Variable Name 300, !- Block Size 1 Value or Variable Name 0.108222, !- Block 1 Cost per Unit Value or Variable Name 700, !- Block Size 2 Value or Variable Name 0.087021, !- Block 2 Cost per Unit Value or Variable Name 1500, !- Block Size 3 Value or Variable Name 0.078420, !- Block 3 Cost per Unit Value or Variable Name remaining, !- Block Size 4 Value or Variable Name 0.058320; !- Block 4 Cost per Unit Value or Variable Name UtilityCost:Charge:Block, AnnualDemandBaseCharge, !- Utility Cost Charge Block Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name , !- Remaining Into Variable TotalDemand, !- Block Size Multiplier Value or Variable Name 190, !- Block Size 1 Value or Variable Name 0.0, !- Block 1 Cost per Unit Value or Variable Name 110, !- Block Size 2 Value or Variable Name 0.051773, !- Block 2 Cost per Unit Value or Variable Name remaining, !- Block Size 3 Value or Variable Name 0.046965; !- Block 3 Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, FuelCostAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.002028; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, QualPollutionControlAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.000536; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, SoxNoxRiderAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.001127; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, DSMRiderAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name -0.000370; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, PurchPowerTrackerAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name -0.000031; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, MidwestISOAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name -0.000216; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, CleanCoalRiderEnergyCharge, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.000833; !- Cost per Unit Value or Variable Name UtilityCost:Qualify, MinDemand75kw, !- Utility Cost Qualify Name PSI_LLF_LowLoadFactorService, !- Tariff Name TotalDemand, !- Variable Name Minimum, !- Qualify Type 75, !- Threshold Value or Variable Name Annual, !- Season Count, !- Threshold Test 12; !- Number of Months UtilityCost:Charge:Simple, TaxofeightPercent, !- Utility Cost Charge Simple Name PSI_LLF_LowLoadFactorService, !- Tariff Name SubTotal, !- Source Variable Annual, !- Season Taxes, !- Category Variable Name 0.08; !- Cost per Unit Value or Variable Name !end PSI_LLF_LowLoadFactorService UtilityCost:Tariff, PSI_CS_CommercialElectricService, !- Name Electricity:Facility, !- Output Meter Name kWh, !- Conversion Factor Choice , !- Energy Conversion Factor , !- Demand Conversion Factor , !- Time of Use Period Schedule Name , !- Season Schedule Name , !- Month Schedule Name , !- Demand Window Length 9.40, !- Monthly Charge or Variable Name , !- Minimum Monthly Charge or Variable Name , !- Real Time Pricing Charge Schedule Name , !- Customer Baseline Load Schedule Name Comm Elect; !- Group Name UtilityCost:Charge:Block, AnnualEnergyCharge, !- Utility Cost Charge Block Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name , !- Remaining Into Variable , !- Block Size Multiplier Value or Variable Name 300, !- Block Size 1 Value or Variable Name 0.082409, !- Block 1 Cost per Unit Value or Variable Name 700, !- Block Size 2 Value or Variable Name 0.072873, !- Block 2 Cost per Unit Value or Variable Name 1500, !- Block Size 3 Value or Variable Name 0.061696, !- Block 3 Cost per Unit Value or Variable Name remaining, !- Block Size 4 Value or Variable Name 0.041179; !- Block 4 Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, FuelCostAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.002028; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, QualPollutionControlAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.000536; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, SoxNoxRiderAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.001127; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, DSMRiderAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.000021; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, PurchPowerTrackerAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.000034; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, MidwestISOAdjustEnergyCharge, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name -0.000203; !- Cost per Unit Value or Variable Name UtilityCost:Charge:Simple, CleanCoalRiderEnergyCharge, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name 0.000807; !- Cost per Unit Value or Variable Name UtilityCost:Qualify, MaxDemand75kw, !- Utility Cost Qualify Name PSI_CS_CommercialElectricService, !- Tariff Name TotalDemand, !- Variable Name Maximum, !- Qualify Type 75, !- Threshold Value or Variable Name Annual, !- Season Count, !- Threshold Test 1; !- Number of Months UtilityCost:Charge:Simple, TaxofeightPercent, !- Utility Cost Charge Simple Name PSI_CS_CommercialElectricService, !- Tariff Name SubTotal, !- Source Variable Annual, !- Season Taxes, !- Category Variable Name 0.08; !- Cost per Unit Value or Variable Name UtilityCost:Tariff, IN_EIAMonthlyRateGas, !- Name NaturalGas:Facility, !- Output Meter Name MCF, !- Conversion Factor Choice , !- Energy Conversion Factor , !- Demand Conversion Factor , !- Time of Use Period Schedule Name , !- Season Schedule Name , !- Month Schedule Name , !- Demand Window Length 0.0, !- Monthly Charge or Variable Name , !- Minimum Monthly Charge or Variable Name , !- Real Time Pricing Charge Schedule Name , !- Customer Baseline Load Schedule Name Comm Gas; !- Group Name UtilityCost:Charge:Simple, MonthlyRateGasCharge, !- Utility Cost Charge Simple Name IN_EIAMonthlyRateGas, !- Tariff Name totalEnergy, !- Source Variable Annual, !- Season EnergyCharges, !- Category Variable Name IN_MonthlyGasRates; !- Cost per Unit Value or Variable Name UtilityCost:Variable, IN_MonthlyGasRates, !- Name IN_EIAMonthlyRateGas, !- Tariff Name Currency, !- Variable Type 8.22, !- January Value 7.51, !- February Value 8.97, !- March Value 9.01, !- April Value 9.16, !- May Value 10.44, !- June Value 10.32, !- July Value 10.13, !- August Value 9.20, !- September Value 8.18, !- October Value 7.83, !- November Value 7.63; !- December Value UtilityCost:Charge:Simple, TaxofEightPercent, !- Utility Cost Charge Simple Name IN_EIAMonthlyRateGas, !- Tariff Name SubTotal, !- Source Variable Annual, !- Season Taxes, !- Category Variable Name 0.08; !- Cost per Unit Value or Variable Name ! ***GENERAL REPORTING*** OutputControl:ReportingTolerances, 0.556, !- Tolerance for Time Heating Setpoint Not Met {deltaC} 0.556; !- Tolerance for Time Cooling Setpoint Not Met {deltaC} Output:SQLite, Simple; !- Option Type Output:VariableDictionary,IDF,Unsorted; Output:Surfaces:List,Details; Output:Surfaces:Drawing,DXF; Output:Constructions,Constructions; ! ***REPORT METERS/VARIABLES*** Output:Meter,Electricity:Facility,HOURLY; Output:Meter,Fans:Electricity,HOURLY; Output:Meter,Cooling:Electricity,HOURLY; Output:Meter,Heating:Electricity,HOURLY; Output:Meter,InteriorLights:Electricity,HOURLY; Output:Meter,InteriorEquipment:Electricity,HOURLY; Output:Meter,NaturalGas:Facility,HOURLY; Output:Meter,Heating:NaturalGas,HOURLY; Output:Meter,InteriorEquipment:NaturalGas,HOURLY; Output:Meter,Water Heater:WaterSystems:NaturalGas,HOURLY; Output:Variable,*,Site Outdoor Air Drybulb Temperature,HOURLY; Output:Variable,*,Site Outdoor Air Humidity Ratio,HOURLY; Output:Variable,*,Site Outdoor Air Relative Humidity,HOURLY; Output:Variable,*,Air System Outdoor Air Flow Fraction,HOURLY; Output:Variable,*,Air System Simulation Cycle On Off Status,HOURLY; Output:Variable,*,Air System Outdoor Air Economizer Status,HOURLY; Output:Variable,*,Air System Total Heating Energy,HOURLY; Output:Variable,*,Air System Total Cooling Energy,HOURLY; Output:Variable,*,Air System Fan Electricity Energy,HOURLY; Output:Variable,*,Fan Electricity Rate,HOURLY; Output:Variable,*,Zone Mean Air Temperature,hourly; ! ***REPORT TABLES*** OutputControl:Table:Style, HTML; !- Column Separator Output:Table:SummaryReports, AnnualBuildingUtilityPerformanceSummary, !- Report 1 Name InputVerificationandResultsSummary, !- Report 2 Name ClimaticDataSummary, !- Report 3 Name EnvelopeSummary, !- Report 4 Name EquipmentSummary, !- Report 5 Name ComponentSizingSummary, !- Report 6 Name HVACSizingSummary, !- Report 7 Name SystemSummary; !- Report 8 Name Output:Table:Monthly, Emissions Data Summary, !- Name 4, !- Digits After Decimal CO2:Facility, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 NOx:Facility, !- Variable or Meter 2 Name SumOrAverage, !- Aggregation Type for Variable or Meter 2 SO2:Facility, !- Variable or Meter 3 Name SumOrAverage, !- Aggregation Type for Variable or Meter 3 PM:Facility, !- Variable or Meter 4 Name SumOrAverage, !- Aggregation Type for Variable or Meter 4 Hg:Facility, !- Variable or Meter 5 Name SumOrAverage, !- Aggregation Type for Variable or Meter 5 WaterEnvironmentalFactors:Facility, !- Variable or Meter 6 Name SumOrAverage, !- Aggregation Type for Variable or Meter 6 Carbon Equivalent:Facility, !- Variable or Meter 7 Name SumOrAverage; !- Aggregation Type for Variable or Meter 7 Output:Table:Monthly, Components of Peak Electrical Demand, !- Name 3, !- Digits After Decimal Electricity:Facility, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Electricity:Facility, !- Variable or Meter 2 Name Maximum, !- Aggregation Type for Variable or Meter 2 InteriorLights:Electricity, !- Variable or Meter 3 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 3 InteriorEquipment:Electricity, !- Variable or Meter 4 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 4 Fans:Electricity, !- Variable or Meter 5 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 5 Heating:Electricity, !- Variable or Meter 6 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 6 Cooling:Electricity, !- Variable or Meter 7 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 7 ExteriorLights:Electricity, !- Variable or Meter 8 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 8 Pumps:Electricity, !- Variable or Meter 9 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 9 HeatRejection:Electricity, !- Variable or Meter 10 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 10 ExteriorEquipment:Electricity, !- Variable or Meter 11 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 11 Humidification:Electricity, !- Variable or Meter 12 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 12 HeatRecovery:Electricity,!- Variable or Meter 13 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 13 WaterSystems:Electricity,!- Variable or Meter 14 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 14 Refrigeration:Electricity, !- Variable or Meter 15 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 15 Generators:Electricity, !- Variable or Meter 16 Name ValueWhenMaximumOrMinimum, !- Aggregation Type for Variable or Meter 16 ElectricityProduced:Facility, !- Variable or Meter 17 Name ValueWhenMaximumOrMinimum; !- Aggregation Type for Variable or Meter 17 Output:Table:Monthly, Heating Part Load Performance, !- Name 0, !- Digits After Decimal Heating Coil NaturalGas Rate, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Heating Coil NaturalGas Rate, !- Variable or Meter 2 Name Maximum; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, Cooling Part Load Performance, !- Name 0, !- Digits After Decimal Cooling Coil Electricity Rate, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Cooling Coil Electricity Rate, !- Variable or Meter 2 Name Maximum; !- Aggregation Type for Variable or Meter 2 Output:Table:Monthly, Fan Part Load Performance, !- Name 0, !- Digits After Decimal Fan Electricity Rate, !- Variable or Meter 1 Name SumOrAverage, !- Aggregation Type for Variable or Meter 1 Fan Electricity Rate, !- Variable or Meter 2 Name Maximum; !- Aggregation Type for Variable or Meter 2 Output:Table:TimeBins, *, !- Key Value Zone Air Relative Humidity, !- Variable Name 60, !- Interval Start 10, !- Interval Size 4; !- Interval Count Output:Table:TimeBins, *, !- Key Value Air System Outdoor Air Flow Fraction, !- Variable Name 0.00, !- Interval Start 0.20, !- Interval Size 5; !- Interval Count Output:Table:TimeBins, *, !- Key Value Availability Manager Night Cycle Control Status, !- Variable Name 0, !- Interval Start 1, !- Interval Size 4; !- Interval Count ! ***ENVIRONMENTAL FACTORS REPORTING*** Output:EnvironmentalImpactFactors, Monthly; !- Reporting Frequency EnvironmentalImpactFactors, 0.663, !- District Heating Efficiency 4.18, !- District Cooling COP {W/W} 0.585, !- Steam Conversion Efficiency 80.7272, !- Total Carbon Equivalent Emission Factor From N2O {kg/kg} 6.2727, !- Total Carbon Equivalent Emission Factor From CH4 {kg/kg} 0.2727; !- Total Carbon Equivalent Emission Factor From CO2 {kg/kg} ! Indiana electricity source and emission factors based on Deru and Torcellini 2007 FuelFactors, Electricity, !- Existing Fuel Resource Name 3.546, !- Source Energy Factor {J/J} , !- Source Energy Schedule Name 3.417E+02, !- CO2 Emission Factor {g/MJ} , !- CO2 Emission Factor Schedule Name 1.186E-01, !- CO Emission Factor {g/MJ} , !- CO Emission Factor Schedule Name 7.472E-01, !- CH4 Emission Factor {g/MJ} , !- CH4 Emission Factor Schedule Name 6.222E-01, !- NOx Emission Factor {g/MJ} , !- NOx Emission Factor Schedule Name 8.028E-03, !- N2O Emission Factor {g/MJ} , !- N2O Emission Factor Schedule Name 1.872E+00, !- SO2 Emission Factor {g/MJ} , !- SO2 Emission Factor Schedule Name 0.0, !- PM Emission Factor {g/MJ} , !- PM Emission Factor Schedule Name 1.739E-02, !- PM10 Emission Factor {g/MJ} , !- PM10 Emission Factor Schedule Name 0.0, !- PM2.5 Emission Factor {g/MJ} , !- PM2.5 Emission Factor Schedule Name 0.0, !- NH3 Emission Factor {g/MJ} , !- NH3 Emission Factor Schedule Name 1.019E-02, !- NMVOC Emission Factor {g/MJ} , !- NMVOC Emission Factor Schedule Name 5.639E-06, !- Hg Emission Factor {g/MJ} , !- Hg Emission Factor Schedule Name 2.778E-05, !- Pb Emission Factor {g/MJ} , !- Pb Emission Factor Schedule Name 0.4309556, !- Water Emission Factor {L/MJ} , !- Water Emission Factor Schedule Name 0, !- Nuclear High Level Emission Factor {g/MJ} , !- Nuclear High Level Emission Factor Schedule Name 0; !- Nuclear Low Level Emission Factor {m3/MJ} ! Deru and Torcellini 2007 ! Source Energy and Emission Factors for Energy Use in Buildings ! NREL/TP-550-38617 ! source factor and Higher Heating Values from Table 5 ! post-combustion emission factors for boiler from Table 9 (with factor of 1000 correction for natural gas) FuelFactors, NaturalGas, !- Existing Fuel Resource Name 1.092, !- Source Energy Factor {J/J} , !- Source Energy Schedule Name 5.21E+01, !- CO2 Emission Factor {g/MJ} , !- CO2 Emission Factor Schedule Name 3.99E-02, !- CO Emission Factor {g/MJ} , !- CO Emission Factor Schedule Name 1.06E-03, !- CH4 Emission Factor {g/MJ} , !- CH4 Emission Factor Schedule Name 4.73E-02, !- NOx Emission Factor {g/MJ} , !- NOx Emission Factor Schedule Name 1.06E-03, !- N2O Emission Factor {g/MJ} , !- N2O Emission Factor Schedule Name 2.68E-04, !- SO2 Emission Factor {g/MJ} , !- SO2 Emission Factor Schedule Name 0.0, !- PM Emission Factor {g/MJ} , !- PM Emission Factor Schedule Name 3.59E-03, !- PM10 Emission Factor {g/MJ} , !- PM10 Emission Factor Schedule Name 0.0, !- PM2.5 Emission Factor {g/MJ} , !- PM2.5 Emission Factor Schedule Name 0, !- NH3 Emission Factor {g/MJ} , !- NH3 Emission Factor Schedule Name 2.61E-03, !- NMVOC Emission Factor {g/MJ} , !- NMVOC Emission Factor Schedule Name 1.11E-07, !- Hg Emission Factor {g/MJ} , !- Hg Emission Factor Schedule Name 2.13E-07, !- Pb Emission Factor {g/MJ} , !- Pb Emission Factor Schedule Name 0, !- Water Emission Factor {L/MJ} , !- Water Emission Factor Schedule Name 0, !- Nuclear High Level Emission Factor {g/MJ} , !- Nuclear High Level Emission Factor Schedule Name 0; !- Nuclear Low Level Emission Factor {m3/MJ}